The AXR-RF Radio Receiver provides wireless reception of AMX radio frequency (RF) transmitters. The AXR-RF connects to an Axcess Central Controller with an AXlink, 4-pin captive-wire connector. When required for large areas, or multiple-room coverage, multiple receivers can be connected in parallel on the AXlink bus.

 

AXlink

 

GND

AXM

AXP

PWR

DEVICE

rear

ON

RADIO

 

front

DATA

AXlink

Installation Guide

AXR-RFRF Receiver

Installation

Configuring the AXR-RF

Use the eight-position DIP switch on, the rear of the AXR-RF, to set the device number. A device number is assigned to devices connected to the AXlink bus. Every device on the bus must have a unique device code. The device number must match the device assignment in the Axcess program. AMX assigns device numbers in three groups:

Axcess Control Cards: 1 - 95

Axcess Bus Boxes: 96 - 127

Axcess Panels/Receivers: 128 - 255

Setting the DIP Switch

Locate the device DIP switch on the rear panel of the AXR-RF and set it to the desired binary device number. The device number is set by the total value of DIP switch positions that are ON (down).

NOTE: If you change the device number, remove and reconnect the AXlink connector. This enters the new device number into memory.

Although the AXR-RF is a bus device, it should be numbered in the 128-255 range, because it is a receiver.

Setting the RF Validation Level

An RF transmitter must send repetitions of data for the receiver to accept it as valid data. In some installations, interference and physical structures may interfere with the receiver's ability to detect the transmitted signal. The signal may become distorted. The receiver can be set to use either two or three repetitions of sequential signals to validate and accept the signal data. To set the receiver's RF level.

FIG. 1 AXR-RF RF Receiver

Specifications

Power Consumption

780 mW; ±12 VDC, 65 mA (max.)

 

 

Dimensions (HWD)

1.5" x 5.09" x 5.27" (3.81 cm x 12.93 cm x 13.39 cm)

 

 

Weight

10.56 oz. (299.37 g)

 

 

 

Front Panel Components:

 

 

Radio data LED

Red LED lights to indicate the AXR-RF has received an RF signal

 

from an AMX transmitter.

 

 

AXlink LED

Green LED that lights to indicate AXlink power/data status as fol-

 

lows:

 

• One blink/second indicates power is active and AXlink

 

 

communication is working.

 

• Two blinks/second indicates the devices specified in the main

 

 

program do not match the devices found.

 

• Three blinks/second indicates there is an AXlink communication

 

 

error

 

• Full on indicates there is either no AXlink control/activity (but the

 

 

power is On) or the Axcess program is not loaded.

 

 

 

Rear Panel Components:

 

 

AXlink connector

4-wire captive-wire AXlink connector for the Central Controller pro-

 

vides data and nominal ±12 VDC power.

 

 

Device number DIP Switch

8-position DIP switch sets the device number for the AXR-RF.

 

 

RF antenna

Receiving antenna screws into the TXC antenna connector. If it is

 

necessary to place the antenna in a remote position, use up to 6 ft.

 

(2 m.) of RG-174 coax cable as an extension. Extend the antenna

 

vertically during use.

 

 

TXC antenna connector

Antenna coaxial connector

 

 

Receive Frequency

418 MHz standard (other frequencies are available)

 

 

Maximum Range

300 feet (91.44 m)

 

 

Enclosure

Molded black matte plastic

 

 

 

Options

Alternate frequencies available

 

PS2.8 Power Supply

 

 

 

1.Locate jumper pins labeled P3 on the circuit board.

2.Position the P3 RF validation jumper to select the number of valid RF data repetitions to be accepted, as shown in FIG. 2:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

 

 

Setting for 3 validations

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting for 2 validations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 2 RF validation jumper settings

Wiring Guidelines

The AXR-RF requires regulated ±12 VDC power to operate properly. The Central Controller supplies power via the AXlink cable. The maximum wiring distance between the Central Controller and AXR-RF is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The table below lists wire sizes and maximum lengths allowable between the AXR-RF and Central Controller. The maximum wiring lengths for using AXlink power are based on a minimum of ±13.5 VDC (no load voltage), available at the Central Controller's power supply.

Wiring Specifications

Wire size

Maximum wiring length

 

 

18 AWG

1805.7 feet (550.37 m)

 

 

20 AWG

1142.4 feet (348.20 m)

 

 

22 AWG

712.2 feet (217.07 m)

 

 

24 AWG

448.9 feet (136.82 m)

 

 

Page 1
Image 1
AMX specifications Wiring Guidelines, Installation Guide, AXR-RF RF Receiver, Overview, Specifications

FAQ

What does the AXR-RF Radio Receiver provide?

The AXR-RF provides wireless reception of AMX radio frequency RF transmitters, connecting to an Axcess Central Controller with an AXlink.

How do I configure the device number for the AXR-RF?

Use the eight-position DIP switch on the rear of the AXR-RF to set the device number, matching the device assignment in the Axcess program.

What is the maximum range of the AXR-RF RF Receiver?

The maximum range of the AXR-RF RF Receiver is 300 feet (91.44 m).