Panel Calibration, Setup, and System Connection

Panel Calibration, Setup, and System Connection

1.Press down and hold both the bottom-left and the bottom-right pushbuttons simultaneously for10 seconds to open the Calibration page.

2.Calibrate the panel by pressing over the two cross-hairs. When done, a "Calibration Successful..." message appears.

3.Press anywhere on the screen to return to the Setup page.

4.From the Setup page, touch the Protected Setup button and enter the panel password into the on-screen keypad. Factory default is 1988.

5.Press the blue Device Number field to open the Device Number keypad and enter a Device Number value for the panel. Factory default is 10001.

6.Press Done when finished entering the device number.

7.Press the on-screen Reboot button to restart the panel.

8.From the Setup > Protected Setup page, touch the Wireless Connection button to open the Wireless Connection page (FIG. 3).

Panel

 

 

 

 

 

 

SSID field

 

 

 

 

 

 

 

 

 

 

 

Wireless

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

Compact

information

 

 

 

 

 

 

 

 

 

 

Flash Card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

info.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 3 Wireless Connection page (MVP wireless connectivity page)

Note: The signal strength bargraph should show a connection to a Wireless Access Point. If there is no signal or IP Address displayed; configuration of your network could be required.

Configuring the MVP-7500 Panel for Unsecured Access

The MVP panel contains an internal 802.11b (Type I) wireless compact flash card that is used for communication with 802.11b Wireless Access Points.

1.Select Protected Setup > Wireless Connection.

2.Locate the Wireless Settings section of the Wireless Connection page. Note: The MVP-7500 wireless communication settings are defaulted to an Open Authentication system. An OPEN system allows the MVP to communicate with the first available Wireless Access Point.

3.Touch the Network Name (SSID) field (FIG. 3).

4.From the Service Set Identifier keyboard, either:

Enter the SSID name assigned to the specific Wireless Access Point (case sensitive) or

Leave this field blank to communicate with the first available Wireless Access Point.

5.Verify the Authentication field reads Open (default).

6.Press the Encryption field until it reads Clear Text (default). The remaining Wireless Settings fields are then greyed-out and read-only.

7.Toggle the DHCP/Static field (within the left IP Settings section) until it reads DHCP.

8.Touch the Protected Setup button to navigate to the Protected Setup page.

9.Press the on-screen Reboot button to both restart the panel and save your changes.

10.Return to the Secondary Connection page to verify that the signal strength quality bargraph is On (indicating a signal).

4.From the Service Set Identifier keyboard, enter the SSID name used on your Wireless Access Point.

5.Press the Encryption field until it reads WEP64 or WEP128. The 64/128 selection reflects the bit-level of encryption security previously configured on your target Access Point.

6.Press the Default Key field until the value matches the identifier value of the key entered into the Wireless Access Point.

The panel’s Default Key value must match the Key value being used on the WAP. For example: Default Key 1 on the panel must match the Key value selected on the Wireless Access Point. You can select from up to four keys.

WEP will not work unless the same default key is set on both the panel and the Wireless Access Point.

7.Under the title WEP Keys section, touch the Key button that corresponds to the Default WEP Key number being used on the Wireless Access Point to launch the WEP Key # keyboard.

8.Using this keyboard, enter the same Current Key value being used on the Wireless Access Point.

9.Click Done when you are finished entering the Current Key for the

selected WEP Key.

Note: If your target Wireless Access Point does not support passphrase key generation, and has previously been setup with a manually entered WEP KEY, you will have to manually enter that same WEP key on your panel.

10.Toggle the DHCP/Static field (within the IP Settings section) until it reads DHCP.

11.Touch the Protected Setup button to navigate to the Protected Setup page.

12.Press the on-screen Reboot button to both restart the panel and save your changes.

13.Return to the Secondary Connection page to verify that the link quality bargraph is On (indicating a signal).

Master Connection Section

The default method used for Master connection is Ethernet.

First - Setup the Master Connection

To configure Ethernet communication:

1.Under the Master Connection column toggle the Connection Type field until the word Ethernet is shown.

2.Press the Mode button:

URL - Enter the System Number (zero for an unknown System Number) and the IP/URL of the Master (Master Port Number is defaulted to 1319).

Listen - Add the MVP’s IP Address into the URL List of the Master (using NetLinx Studio). This mode sets the MVP panel to "listen" for broadcasts from the Master (using the panel IP from its URL list).

Auto - Enter the System Number of the NetLinx Master. This mode instructs the MVP to search for a Master that uses the same System Number (assigned within the Master Connection

section) and that resides on the same subnet.

Note: Refer to the Configuring your NetLinx Master for Communication section of the MVP Wireless Modero Touch Panels Instruction Manual for detailed Mode parameter information.

Second - Setup the IP Settings (Panel Communication)

Toggle the on-screen DHCP/Static button to select the appropriate setting for your system.

DHCP - With this setting, other settings are greyed-out and do not apply. Typically the Host Name can be left blank. These fields (“pulled” from the Ethernet connection) are filled-in by the panel after the unit is rebooted.

Note: The signal strength bargraph should show a connection to a Wireless Access Point. If there is no signal or IP Address displayed; configuration of your network could be required.

Configuring the MVP-7500 Panel for Secured Access

1.Select Protected Setup > Wireless Connection.

2.Locate to the Wireless Settings section of the Wireless Connection page.

3.Touch the Network Name (SSID) field (FIG. 3).

Static IP - With this setting, you must enter the network information as provided by your Network Administrator.

Note: When done, press the on-screen Reboot button. (on the Protected Setup page) after any changes are made to the Communication Parameters.

AMX Corporation reserves the right to alter specifications without notice at any time.

93-5965-01

REV: C

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

 

 

036-004-2745 12/03 ©2003

AMX Corporation. All rights reserved. The AMX logo is a trademark of AMX Corporation.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

Page 2
Image 2
AMX quick start Panel Calibration, Setup, and System Connection, Configuring the MVP-7500 Panel for Unsecured Access