NOTE: Anton/Bauer strongly recommends that batteries are kept on the PowerCharger until ready for use. The Lifesaver mode will keep them 100% charged and ready for use.

LCD Indications

Each PowerCharger’s liquid crystal display (LCD) will display the status of each battery, as well as, important PowerCharger operating indications. The following information explains the indications which appear in the LCD.

The levels of the LCD display on each PowerCharger can be obtained by pressing the DISPLAY, or in some cases TEST, button on the PowerCharger front panel.

- - - - - - -1

2 - - - - - - -

 

 

 

 

 

 

 

1 - - - - - - -

2 - - - - - - -

 

3 - - - - - - -

4 - - - - - - -

 

 

 

 

 

 

 

1—WAIT

2—READY

 

3—CHARGE

4—READY

 

 

 

DUAL 2701 Rev. #3.xx

Discharger NOT INSTALLED

 

1—Waiting to Charge

 

 

 

PROPAC 14

16.5 V

 

 

 

 

 

 

 

 

 

 

2—READY (Lifesaver)

4.0

 

PROPAC 14D 100% 16.5 V

2—Ser# 96280 Mar98 4.0

118 cycles

VCO 27oC

The Main Display shows the general status of each battery mounted to the PowerCharger. This display is immediately returned to following self test and after viewing any other screen.

Both the two position (above) and four position Main Displays will show a series of dashes when a battery has not been mounted to the PowerCharger.

The Main Display of the PowerCharger will show the abbreviated status of each battery on the main unit. Batteries mounted to a charge expansion module (XM) will NOT appear in the display.

The Signature Display can be viewed by pressing and holding the TEST button from the Main Display on the PowerCharger to obtain model information, Software revision number and installation of DDM (discharger).

The Primary Position Display is obtained by pressing the DISPLAY button repeatedly until the position number for the battery desired is displayed. This view further identifies the status of the battery, its model number (chemistry and voltage), as well as current battery voltage.

The Primary Position Display will additionally display the available capacity when a DIGITAL battery is used, both in percent and in ampere hours.

The Secondary Position is obtained by pressing and holding the DISPLAY button while viewing the primary position display. This Secondary display is available only with DIGITAL batteries and is used to obtain information transmitted from the battery to the charger including battery serial number, date of manufacture, number of cycles, “learned” capacity, type of stage one charging cut-off experienced and battery temperature.

6

Page 8
Image 8
Anton/Bauer 2700, 2400 owner manual Wait Ready Charge, Propac