Priority Battery Function
A unique operating feature of all PowerChargers allows the operator to select any battery on any charge position as a PRIORITY BATTERY. While connecting a battery to any charge position, hold the DISPLAY button until an audible indication sounds and the LCD indicates:
PRIORITY BATTERY
The PowerCharger will interrupt the charging of any other battery and address the Priority Battery immediately (assuming it is within a safe charging parameters). When priority charging is complete, the charger will return to addressing the other batteries on the charger.
NOTE: This function is unavailable if the AUTOCAL mode has been requested by the charger.
DDM (DIAGNOSTIC/DISCHARGE MODULE)
(standard on Model QUAD 2702)
The DDM is a modular addition which will upgrade any InterActive 2000 PowerCharger to a complete battery management system. A standard feature with the QUAD 2702, the DDM can be easily added to any model PowerCharger, at any time. With this module installed, the PowerCharger becomes a complete battery management system, capable of testing battery capacity and identifying battery anomalies before they appear in the field.
The DDM will perform a standard or a 24 hour test. The standard test is a full
Test time will vary with battery condition and watt hour rating. The standard test will require a minimum of 6 hours to a maximum of about 12 hours. The 24 hour test will require an additional 24 hours as the battery undergoes a 24 hour rest time to identify