Antunes, AJ 9300586 Installation, EGG STATION ES-600 & ES-1200, Unpacking, Equipment Setup

Models: 9300572 9300570 9300576 9300580 9300584 9300582 9300586

1 16
Download 16 pages 47.6 Kb
Page 7
Image 7
INSTALLATION

EGG STATION (ES-600 & ES-1200)

INSTALLATION

Unpacking

1.Remove unit and all packing materials from ship- ping carton.

NOTE: If any parts are missing or damaged, con- tact Antunes Technical Service IMMEDIATELY at

1-877-392-7854 (Toll free in the U.S. and Canada) or 630-784-1000.)

2.Remove information packet.

3.Remove all packing materials and protective cov- erings from the unit.

4.Wipe all surfaces of the unit with a hot damp cloth.

NOTE: Do not use a dripping wet cloth. Wring it out before use.

5.Clean the Egg Rings, Egg Rack, cover and ser- vice pans in hot, soapy water. Rinse in clear water and allow to air dry.

6.Reassemble all parts to unit.

Equipment Setup

When placing the unit into service, pay attention to the following guidelines:

Make sure power to the unit is off and the unit is at room temperature.

Do not block or cover any openings on the unit.

Do not immerse cord or plug in water.

Keep cord away from heated surfaces.

Do not allow cord to hang over edge of table or counter.

Place the unit on a sturdy, level table or other work surface. Turn off the Rocker Switch (power On/Off) before proceeding.

Ensure that the line voltage corresponds to the stated voltage on the unit’s specification label. If unsure, have an electrician confirm correct line voltage before connecting unit.

Unpacking CAUTION Equipment Setup

All electrical service connections must be in accordance with local electrical codes and any other applicable codes.

Manual background WARNING Manual background

ELECTRICAL SHOCK HAZARD.

FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESULT IN SERIOUS INJURY OR DEATH.

Electrical ground is required on this appliance.

Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

Do not use an extension cord with this appli- ance.

The unit should be grounded according to local electrical codes to prevent the possibil- ity of electrical shock. It requires a grounded receptacle with separate electrical lines, pro- tected by fuses or circuit breaker of the proper rating.

Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.

Manual background IMPORTANT Manual background

When installing the unit, use a leveler to ensure that the table/cart is level and that the unit is level when placed. If necessary, adjust the two front bottom legs of the unit to level it. Failure to level the table and/or unit may result in unevenly cooked product.

P/N 1010871 Rev. D 08/05

7

Page 7
Image 7
Antunes, AJ 9300586, 9300582, 9300584, 9300580 Installation, EGG STATION ES-600 & ES-1200, Unpacking, Equipment Setup