EGG STATION (ES-600 & ES-1200)
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing.
Problem | Possible Cause | Corrective Action |
|
|
|
Unit fails to operate and | No power/low power. | Make sure the Rocker Switch (power On/Off) |
control panel lights fail |
| is ON and the power cord is locked into place. |
to signal on. |
| Check the main circuit breakers. |
| Inoperable electrical outlet. | Plug the power cord into a different outlet of |
|
| same amperage rating. |
| Inoperable Rocker Switch (power | Contact your maintenance person or an |
| On/Off) . | Authorized Service Agency. |
| Inoperable Power Cord. |
|
| Loose connections. |
|
Unit fails to heat. | Loose connections. | Contact your maintenance person or an |
| Inoperable Platen. | Authorized Service Agency. |
|
| |
| Low voltage. |
|
| Inoperable |
|
| Inoperable Thermocouple. |
|
| Inoperable Solid State Relay. |
|
Eggs do not cook prop- | Using refrigerated eggs and the time | Set time selector switch to 2’ 30” when using |
erly. | selector switch is set for 2’ 00”. | refrigerated eggs. |
| Time selector switch is set for 2’ 30” | Set time selector switch to 2’ 00” when using |
| (eggs overcooked). | room temperature eggs. |
| Incorrect amount of water added to | Fill trough in cover with water before starting time |
| trough in cover. | cycle. |
| Platen Temperature is too low or too | Check temperature according to the Maintenance |
| high. | section of this manual.. |
| Loose connections. | Contact your Authorized Service Agency. |
| Unit/Table is not level | Level the table and unit as necessary. |
|
|
|
Eggs sticking to Platen. | Dirty Platen. | Clean Platen. |
| Insufficient butter being used. | Refer to the Operating section of this manual. |
Eggs sticking to Egg | Insufficient butter being used. | Refer to the Operating section of this manual. |
Rings. | Dirty Egg Rings. | Do not use an abrasive scrubbing pad to clean |
| ||
|
| Egg Rings. |
| Inoperable Egg Ring. | Replace Egg Ring. |
Not signaling on “Bacon” | Inoperable indicator light or audio | Contact your maintenance person or an |
or “Ready”. | signal. | Authorized Service Agency. |
| Inoperable Control Board. |
|
| Loose connection. |
|
| Bacon Timer is disabled | Enable the Bacon Timer according to the |
|
| Operation Section of this manual |
|
|
|
If the troubleshooting steps listed do not solve your problem, contact an A.J. Antunes Authorized Service Agency for further assistance.
P/N 1010871 Rev. D 08/05 | 11 |