Antunes, AJ UF-420/440 OPERATION continued, Programming Timer During Startup, Fi - Flush Interval

Models: UF-420/440

1 18
Download 18 pages 57.23 Kb
Page 12
Image 12
OPERATION (continued)

UF SERIES WATER FILTRATION SYSTEM

OPERATION (continued)

Programming Timer During Startup

NOTE: Once the UF unit is powered up, the

LED display cycles through the default or current settings: Flush Duration (Fd) and its setting will be followed by Flush Interval (Fi) and its settings. At any time during this sequence (which lasts approximately 30 seconds) the UF unit can be pro- grammed.

SETTING THE FLUSH INTERVAL (FI)

1.When Fi (Figure 5) is displayed, press and release the Start button to view the current set- ting.

2.To make a program change, press and hold the Start button to scroll through settings - release the Start button at the desired setting (Figure 5).

3.If, after ten seconds, the Start button is not pressed, the unit automatically returns to the Flush Interval Mode.

NOTE: Flush Interval times are displayed in ten minute intervals. After fifty minutes, Flush Interval times are displayed in hours (Table A).

SETTING FLUSH DURATION (FD)

2.When Fd is displayed, press and release the Start button to view the current setting (Figure 8).

3.To make a program change, press and hold the Start button to scroll through settings - release the Start button at the desired setting (Figure 9).

4.After ten seconds, unless button is depressed, unit automatically returns to Flush Interval Mode.

NOTE: Fd times are displayed in 5 second intervals up to 60 seconds (Table A).

Fi - Flush Interval
Fd - Flush Duration

Mode

 

Mode

1- (10 minutes)

5

(5 seconds)

5- (50 Minutes )

10

(10 seconds)

01 (1 Hour)

15

(15 Seconds)

12 (12 Hours)

30

(30 Seconds)

24 (24 hours)

60

(60 Seconds)

Table A. LED Display Settings

START

Figure 6. LED Display for Flush Interval Mode

START

Figure 7. Time Setting Fi Mode (22 Hours)

START

Figure 8. LED Display for Flush Duration Mode

START

Figure 9. Time Setting Fd Mode (55 Seconds)

Programming Timer During Interval (FI) Mode

TO SET FI - FLUSH INTERVAL MODE

NOTE: After power-up and cycling - Fi time setting displays a flashing decimal point.

1.Press and hold down start button for four seconds. Release button, LED will display Fd followed by its setting.

2.When Fi (Figure 10) is displayed, press and release button to view current setting.

3.To make a change, press and hold down the start

12

P/N 1010827 Rev. D 04/06

Page 12
Image 12
Antunes, AJ UF-420/440 OPERATION continued, Programming Timer During Startup, Programming Timer During Interval FI Mode