UF SERIES WATER FILTRATION SYSTEM
INSTALLATION
Unpacking
1.Remove the system and all packing materials from the shipping carton.
2.Remove all packing materials and protective cov- erings from the system
3.Remove the information packet. To prevent any delay in obtaining warranty coverage, fill out and mail the warranty card.
NOTE: If any parts are damaged, contact Antunes Filtration Technologies IMMEDIATELY at
plastic connections of the system. This will reduce the possibility of cracking the connections due to overtight- ening.
If soldered plumbing is used, do not apply heat to, or near, the filtration system. The use of union
SUGGESTED TOOLS AND SUPPLIES FOR INSTALLATION
The following tools and supplies are suggested to make the installation easier:
2991 (in the U.S. only) or 1-630-784-1000.
Equipment Setup
GENERAL
When placing the unit into service, pay attention to the following guidelines:
• | Make sure power to the unit is off. |
• | Do not immerse cord or plug in water. |
•Screwdriver
•Drill with bits
•Strap wrench
(up to 6” diameter)
•Tape measure
•Two gallon bucket
•Fresh 5 1/4% liq- uid chlorine bleach (such as Clorox®)
•Adjustable wrenches
•Pipe wrenches
•Level
•Pipe dope or Teflon® tape
• Keep cord away from heated surfaces. |
ELECTRICAL
Ensure that the line voltage corresponds to the stated voltage on the units specification label. Make sure that the plug on the power cord from the system and the outlet match. For proper operation, and to ensure the highest quality water from the system, make sure that the system is not connected to a switched electrical outlet.
PLUMBING
NOTE: This unit is designed to use tap water not to exceed 104°F (40°C).
The
• | Water Inlet | 3/4” NPT |
• | Permeate (Product Water) | 3/4” NPT |
• | Drain | 3/4” NPT |
When making a plumbing connection to the system, remember to use a
Do not
CAUTION
This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code Administrators, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
CAUTION
Water pressure must not exceed a membrane burst pressure of 7 bar (100 psi). To reduce water pressure, install a water pressure regulator and set water pressure to suit application. Note that the trans membrane pressure must be .5 - 2.5 bar (7 - 36 psi).
Locating and Mounting the system
Consider these points before mounting the system:
•Note the location of the water supply, drain, and an appropriate electrical outlet when choosing a mounting location.
•Remember to allow for access to the timer/ programmer controls.
•Do not mount the system above any electrical equipment, or above items that may be damaged if they get wet.
8 | P/N 1010827 Rev. D 04/06 |