UF SERIES WATER FILTRATION SYSTEM
OPERATION (continued)
button to scroll through settings - release button at desired setting (Figure 11).
4.After ten seconds, if start button is not pressed, unit automatically returns to Flush Interval Mode.
NOTE: Fi times are displayed in ten minute inter- vals, after fifty minutes they are displayed in hours (Table B).
TO SET FD - FLUSH DURATION MODE
1.Press and hold the Start button for four seconds. Release button, LED will display Fd.
2.When Fd is displayed (Figure 12), press and release the Start button to view the current setting
3.To make a change, press and hold the Start but- ton to scroll through settings - release the Start button at desired setting (Figure 13).
4.If, after ten seconds, the Start button is not pressed, the unit automatically returns to the Flush Interval Mode.
NOTE: Fd times are displayed in 5 second intervals up to 60 seconds (Table B).
Fi - Flush Interval | Fd - Flush Duration | |
Mode |
| Mode |
1- (10 minutes) | 5 | (5 seconds) |
5- (50 Minutes ) | 10 | (10 seconds) |
01 (1 Hour) | 15 | (15 Seconds) |
12 (12 Hours) | 30 | (30 Seconds) |
24 (24 hours) | 60 | (60 Seconds) |
Table B. LED Display Settings
START
Figure 12. LED Display for Flush Duration
START
Figure 13. Time Display for Fd Mode (15 Seconds)
Manual Flushing
NOTE: Manual flushing only works when unit is in Flush Interval Mode (Fi).
While the unit is in Flush Interval Mode (decimal point flashing), hold the start button down for
START
Figure 10. Fi - LED Display for Flush Interval Mode
START
Figure 11. Time display for Fi Mode (30 Minutes)
P/N 1010827 Rev. D 04/06 | 13 |