APC 865 W, 120 V, J35B, J25B, 1440 VA Troubleshooting, Problem, Possible Cause, Corrective Action

Models: 120 V

1 41
Download 41 pages 16.76 Kb
Page 13
Image 13
Troubleshooting

Troubleshooting

Problem

Possible Cause

Corrective Action

 

 

 

The unit will not turn on.

The unit is not connected to utility power.

Ensure that the unit is securely connected to

 

 

a utility power outlet.

 

 

 

 

The internal battery is not connected.

Connect the battery.

The unit does not provide

Ensure that essential equipment is not

Disconnect equipment from the SURGE

power during a utility power

plugged into a SURGE ONLY outlet.

ONLY outlet and re-connect to a Battery

outage.

 

Backup outlet.

 

 

 

The unit is operating on

The plug has partially pulled out of the

Ensure that the plug is fully inserted into

battery power, while connected

wall outlet, the wall outlet is no longer

the wall outlet. Ensure that the wall outlet is

to utility power.

receiving utility power, or the circuit

receiving utility power by checking it with

 

breaker has been tripped.

another device.

 

 

 

 

The unit is performing an automatic self

No action is necessary.

 

test.

 

The utility input voltage is out of range, the frequency is out of range, or the waveform is distorted.

Adjust the transfer voltage and sensitivity range.

The circuit breaker has been tripped.

Disconnect non-essential equipment from the unit. Reset the circuit breaker. Re- connect equipment one item at a time. If the circuit breaker is tripped again, disconnect the device that caused the trip.

The unit does not provide the expected amount of backup time.

Battery Backup outlets may be fully or

Disconnect non-essential equipment from

improperly loaded.

the Battery Backup outlets and connect the

 

equipment to SURGE ONLY outlets.

 

 

The battery was recently discharged due

Charge the battery cartridge for 16 hours.

to a power outage and has not fully

 

recharged.

 

 

 

The battery has reached the end of its

Replace the battery.

useful life.

 

Power is not supplied to some outlets.

Power to the Controlled outlets has intentionally been turned off.

Confirm that the correct peripherals are connected to Controlled outlets. If this feature is not desired, disable the Power- Saving Master and Controlled outlets.

The Controlled outlets are not supplying power, even though the Master device is not in sleep mode.

The Master Outlet threshold may be incorrectly set.

Adjust the threshold when the Master outlet signals the Controlled outlets to shut down.