APC BE600N-BR Specifications, Troubleshooting, Replace the Battery, Warranty, Solution, Input

Models: BE600N-BR

1 4
Download 4 pages 6.51 Kb
Page 3
Image 3
Specifications

Specifications

 

 

 

Voltage

115 Vac or 220 Vac Nominal

Input

 

Frequency

60 Hz + 3

 

 

 

 

 

Brownout Transfers

115 Vac: 88 Vac Typical, 220 Vac: 176 Vac Typical

 

 

 

 

 

 

 

 

 

 

 

 

Over-voltage Transfer

115 Vac: 143 Vac Typical, 220 Vac: 264 Vac Typical

 

 

 

 

 

 

 

 

 

UPS Capacity (6 outlets)

600 VA, 360 W

 

 

 

 

 

 

Output

 

Voltage - On Battery

115 Vac +6%, -10% (step-approximated sine wave)

 

 

 

 

 

Frequency - On Battery

60 Hz + 1

 

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

5 ms Typical, 8 ms maximum

 

 

 

 

 

 

Bivolt

 

Automatic Bivolt

115 Vac: 88-143 Vac, 220 Vac: 176-264 Vac

 

 

 

 

 

 

Circuit Breaker Ratings

 

115 Vac: 8 A, 220 Vac: 5 A

 

 

 

 

 

 

 

 

 

 

 

AC Surge Protection

Full time, 365 joules

 

 

 

 

 

 

Protection and Filter

 

Modem/Phone/FAX Surge Protection

Single line (2-wire)

 

 

 

 

 

EMI/RFI Filter

Full time

 

 

 

 

 

 

 

 

 

 

 

 

AC Input

Circuit breaker reset

 

 

 

 

 

 

Battery

 

Type

Sealed, maintenance-free, lead acid

 

 

 

 

 

Average Life

2 - 4 years depending on the number of discharge cycles and environmental

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

Physical

 

Net Weight

8 kg (18 lb)

 

 

 

 

 

Dimensions H x W x D

10 cm x 34 cm x 21 cm

 

 

 

 

 

 

4 in x 10 in x 7 in

 

 

 

 

Troubleshooting

 

 

 

 

Problem and Possible Cause

Solution

 

 

 

 

 

The Back-UPS will not turn on

 

 

 

 

 

 

 

The Back-UPS has not been turned on.

Press the Power on button.

 

 

 

 

 

The Back-UPS is not connected to utility power, there is no utility power

Make sure the power cord is securely connected to the wall outlet, and that there is

 

available at the wall outlet, or the utility power is experiencing a brownout or over

utility power available at the wall outlet.Where applicable, check that the wall outlet

 

voltage condition.

 

 

is switched on.

Connected equipment loses power

A Back-UPS overload condition has occurred.

Remove all nonessential equipment connected to the outlets. One at a time reconnect equipment to the Back-UPS.

The Back-UPS battery is completely discharged.

Connect the Back-UPS to utility power and allow the battery to recharge for eight hours.

PowerChute software has performed a shutdown due to a power failure.

The Back-UPS is operating normally.

 

 

The Back-UPS may require service.

Contact APC Technical Support for more in depth troubleshooting.

 

The Back-UPS is on, the Check Battery LED flashes and the unit emits a constant tone

 

 

The battery is disconnected.

Refer to the Connect the Battery section in this guide.

The Power On LED is illuminated and the Back-UPS beeps four times every 30 seconds

The Back-UPS is operating on battery power.

The Back-UPS is operating normally on battery power. At this point the user should save all open files, and shutdown the computer. When utility power is restored the battery will recharge.

The Back-UPS has an inadequate battery runtime

The battery is not fully charged.

Leave the Back-UPS connected to utility power for eight hours while the battery charges to full capacity.

The battery life cycle is near completion.

As the battery ages the runtime capability decreases. To order a replacement battery contact APC at www.apc.com.

Replace the Battery

Pb

Pb

Deliver used batteries to a CASC facility.

Request that CASC replace the battery with an APC approved battery.

Contact APC through the APC Web site www.apc.com, for the location of the nearest CASC facility.

Warranty

The standard warranty is 2 years from the date of purchase. APC standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The customer pays for shipping to APC, and APC pays ground freight transportation costs back to the customer.

3

Page 3
Image 3
APC BE600N-BR Specifications, Troubleshooting, Replace the Battery, Warranty, Deliver used batteries to a CASC facility