Feature Quick-Reference

Function

Button

Timing UPS Description (seconds) Status

Power

POWER ON

POWER OFF

Display

0.2

Off

Press the POWER ON/OFF button to turn on the Back-UPS and operate on

 

 

AC power.

 

 

If AC input power is not available the Back-UPS will operate on battery

 

 

power.

2

On

Press the POWER ON/OFF button to turn off the Back-UPS.

 

 

The Back-UPS will continue to provide surge protection to the Surge

 

 

Protection outlets.

 

 

 

Status Inquiry

 

 

 

0.2

On

Verify the status or condition of the Back-UPS. The LCD will illuminate

 

 

 

 

 

 

for 60 seconds.

 

 

 

 

 

 

 

Power-Saving mode:

 

 

 

2

On

The LCD will illuminate and the Back-UPS will beep to confirm

Continuous

 

 

 

 

 

Continuous Illumination mode is activated.

Illumination

 

 

 

 

 

The LCD will extinguish and the Back-UPS will beep to confirm that

 

 

 

 

 

 

Power-Savingmode is activated. While in Power-Savingmode, the

 

 

 

 

 

 

LCD will illuminate if a button is pressed, then extinguish after 60

 

 

 

 

 

 

seconds of no activity.

 

 

 

 

 

 

 

Mute

 

 

 

 

 

 

 

 

 

 

 

 

 

Event Specific

 

 

 

0.2

On

Disable any audible alarms caused by an event.

 

 

 

 

 

 

 

General Status

 

 

 

2

On

Enable or disable the audible alarms. The Mute icon will illuminate and

Enable/Disable

 

 

 

 

 

the Back-UPS will beep one time. The Mute feature will not activate

 

 

 

 

 

 

unless the Back-UPS is operating on battery power.

 

 

 

 

 

 

 

Sensitivity

 

 

 

6

Off

The Load Capacity icon will flash to indicate the Back-UPS is in

 

 

 

 

 

 

Program mode. Use the POWER ON/OFF button to scroll through and

 

 

 

 

 

 

select Low, Medium, and High sensitivity levels. The Back-UPS will

 

 

 

 

 

 

beep to confirm the selection. Refer to “Back-UPS sensitivity settings” on

 

 

 

 

 

 

page 4 for details.

MASTER/

 

 

 

2

On

The leaf icon will extinguish to indicate the MASTER outlet feature is

CONTROLLED

 

 

 

 

 

disabled or illuminate to indicate the MASTER outlet feature is enabled.

outlet Enable/

 

 

 

 

 

The Back-UPS will beep once.

Disable

 

 

 

 

 

 

Master/Enable

 

 

 

6

On

While calibrating the threshold setting, the device connected to the

threshold calibration

 

 

 

 

 

MASTER outlet should be turned off or placed in Standby or Sleep mode.

 

 

 

 

 

 

Once the threshold setting has been selected the Power-Savingicon will

 

 

 

 

 

 

flash 3 times and beep 3 times.

Self-Test (manual)

 

 

 

6

On

The Back-UPS will run a test of the internal battery.

 

 

 

 

 

 

Note: This will happen automatically when the Back-UPS is turned on.

 

 

 

 

 

 

 

 

 

 

 

 

 

Event Reset

 

 

 

0.2

On

When the Event screen is visible, press and hold DISPLAY, then press the

 

 

 

 

 

 

POWER button to clear the AC failure event counter.

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Reset

 

 

 

2

Fault

After a fault has been identified, press the POWER ON/OFF button to

 

 

 

 

 

 

remove the visual indication and return to standby status.

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and Operation Back-UPS BX1300G/BN1350G/BX1500G

7

Page 7
Image 7
APC BX1300G, BN1350G Feature Quick-Reference, Protection outlets, Continuous Continuous Illumination mode is activated