www.apc.com | User Guide |
|
Connect Battery
1For safety, the
1 | TURN the |
slide the battery compartment |
cover off of the battery housing.
2 | LIFT the battery out of the compartment and connect the black wire to the negative |
terminal. Ensure the batteries are installed as shown below. |
Slide the battery compartment cover
3 completely onto the
Battery Backup Surge Protection
2
Connect Equipment
Place the
- Excessive heat
- Excessive humidity or contact with fluids
Plug the
These outlets are powered whenever the
surge protector or power strip.
(brownouts,
| ® |
|
| w w w.apc.com | AC LINE |
|
| CORD |
| Battery Backup | Surge Protection |
| Surge Protection Only | |
|
| |
POWER ON/ | 5 5 0 |
|
|
| |
REPLACE BATTERY |
|
|
INDICATOR | Replace Battery |
|
| Power On |
|
Surge Protection Only
These outlets provide
Connect FAX/Modem/Phone
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the
BUILDING WIRING
FAULT INDICATOR
| Building |
| |
| Wiring | CAUTION - Refer to bottom | |
| Fault | ||
FROM WALL JACK | of unit for safety markings. | ||
| |||
| Wall Push to Reset | ||
|
| Circut Breaker | |
|
| Outlet | |
DATALINE OUTPUT TO |
| Phone/Fax | |
DSL MODEM or PHONE |
| Modem/ | |
|
| ||
|
| Data Port | |
TO COMPUTER | CIRCUIT BREAKER | ||
USB PORT | PUSH TO RESET |
3Power On and Install Software
Press the ON/OFF switch to power the unit ON.
A single short beep and the green “Power On” indicator confirms that
The
If the red Building Wiring Fault indicator (located on the end near the power cord) is lit, your building wiring presents a shock hazard that should be corrected by a qualified electrician.
Install the PowerChute Personal® Edition software
Place the PowerChute Personal Edition CD- ROM into your computer and follow the installation instructions on the screen.
Status | Visual Indications | Audible Indication | Alarm Terminates | |
| (Power On - Green) |
| When | |
| (Replace Battery - Red) |
|
| |
Power On - UPS is supplying conditioned | Power On LED - ON | None | Not applicable. | |
utility power to the load. |
|
|
|
|
On Battery - UPS is supplying battery | Power On LED | - ON (off | Beeping 4 times every | UPS transfers back to |
power to the load connected to the Battery | during beep) |
| 30 seconds | Power On operation, or |
outlets. |
|
|
| when UPS is turned off. |
Low Battery Warning - UPS is supplying | Power on LED | - flashing | Rapid beeping (every | UPS transfers back to |
battery power to the load connected to the |
|
| 1/2 second) | normal operation, or |
Battery outlets and the battery is near |
|
|
| when UPS is turned off. |
exhaustion. |
|
|
|
|
Replace Battery - The battery is | Replace Battery LED - | Constant tone | UPS turned off with the | |
disconnected. | flashing |
|
| power switch. |
The battery is in need of charging or is at | Power On and Replace | Constant tone |
| |
the end of its usual life and must be | Battery LEDs- | Flashing |
|
|
replaced. | (alternating) |
|
|
|
Overload Shutdown - During On Battery | None |
| Constant tone | UPS turned off with the |
operation a battery power supplied outlet |
|
|
| power switch. |
overload was detected. |
|
|
|
|
Sleep Mode - During On Battery operation | None |
| Beeping once every 4 | Utility power is restored, |
the battery power has been completely |
|
| seconds | or if utility power is not |
exhausted and the UPS is waiting for utility |
|
|
| restored within 32 |
power to return to normal. |
|
|
| seconds, or the UPS is |
|
|
|
| turned off. |
Building Wiring Fault - Your building | Building Wiring Fault LED | None | UPS is unplugged, or is | |
wiring presents a shock hazard that should | (red) - ON |
|
| plugged into a properly |
be corrected by a licensed electrician. |
|
|
| wired outlet. |
See the Troubleshooting section for additional assistance.