Image 9

Configuration

UPS Settings

Start up settings

Configure these settings at initial start up, using the display interface or PowerChutesoftware.

Note: During start up, use the display interface to configure these settings. If nothing is selected, the unit will use the default settings.

Function

Factory Default Options

Description

 

 

 

 

 

 

• English

 

 

 

• French*

The language for the display interface.

Language

English

• German*

 

• Spanish*

 

• Italian*

*Language options will vary by model.

 

• Portuguese*

 

Local Power Good

Quality

Good

Fair

Poor

Select the quality of input utility power.

If Good is selected, the unit will go on battery power more often to provide the cleanest power supply to the connected equipment.

If Poor is selected, the UPS will tolerate more fluctuations in power and will go on battery power less often.

If unsure of the local power quality, select Good.

Menu Type Standard

Standard or

The Standard menus display a limited set of menus and options.

Advanced

The Advanced menus include all parameters.

 

General Settings

Configure these settings at any time, using the display interface or PowerChute software.

Function Factory Default

Options

Description

High

120 V: 140 Vac

120 V: 140-150 Vac

 

 

transfer

 

 

point

230 V: 280 Vac

230 V: 280-300 Vac

To avoid unnecessary battery usage, set the transfer point higher if the utility voltage is chronically high and the connected equipment is known to work under this condition. The POWER QUALITY setting will automatically change this setting.

Note: Use the Advanced Menus to configure this setting.

Low

120

V: 85 Vac

120

V: 75-85 Vac

 

 

 

 

Transfer

230

V: 170 Vac

230

V: 150-170 Vac

Point

Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this condition.This setting may also be adjusted using the power quality setting.

Note: Use the Advanced Menus to configure this setting.

Nominal

230 V: 230 Vac

230 V: 220, 230, 240 Vac Set the nominal output voltage of the UPS on battery. This

Output

120 V: 120 Vac

120 Vac: N/A

is available on 230 V models only.

Voltage

 

 

 

Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U