Apple 3400C/200, G3 manual Hardware failure, Reset PRAM, occurs four-tone, error chord sequence

Models: 3400C/200 G3

1 210
Download 210 pages 31.8 Kb
Page 47
Image 47
Hardware failure

 

Troubleshooting

 

Symptom Charts/Startup - 3

Hardware failure

1

Reset PRAM.

occurs (four-tone

2

Remove floppy drive from media bay and restart computer. If

error chord sequence

3

startup sequence is normal, insert floppy drive and retest.

sounds after startup

Replace floppy mechanism.

chord)

4

Disconnect hard drive cable and restart computer. If startup

 

 

5

sequence is normal, reconnect cable and retest.

 

 

Replace hard drive.

 

 

6

Replace logic board.

Startup failure

Upgrade to System Enabler 1.2.1 or later. Refer to Apple Software

occurs when using

Updates on Service Source Companion CD.

minimum System

 

 

Folder and System

 

 

7.6.

 

 

 

Page 47
Image 47
Apple 3400C/200 Hardware failure, Reset PRAM, occurs four-tone, error chord sequence, sounds after startup, minimum System