Model 1730A Compact Dehumidifier Installation Instructions
WARNING
1.120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation. Leave power disconnected until installation is complete.
2.Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork.
3.Dropping may cause personal injury or equipment damage. Handle with care.
4.Do not remove the inlet or outlet screen. Both screens are required to protect from moving parts and electrical components.
CAUTION
1.Do not use in pool applications.
2.If unit has been shipped or stored on its side, wait 24 hours before running.
3.Do not use solvents or cleaners on or near the circuit board.
SPECIFICATIONS
Dimensions: Width: 12.5” cabinet, 13” with doors
Height: 14.5” cabinet, 17” with 2.5” leveling feet
Length: 22” cabinet, 27” with collars
Weight: 65 lbs.
Capacity: 65 pints/day @ 150 cfm
AHAM
Efficiency: 1.8 Liters per kilowatt hour
AHAM
Power: 115VAC, 60 Hz, 8A Operating Current
Unit equipped with 8 ft. grounded power cord Dedicated 15 Amp circuit recommended
Airflow: |
|
| |
P ("w.c.) | Airflow (cfm) | ||
| |||
| 0 | 230 | |
| 0.25 | 190 | |
| 0.50 | 150 |
Inlet Air Operating Conditions: 60°F to 95°F, 30% RH to 99% RH
Installation Conditions: 40°F to 140°F, 0% RH to 99% RH
Evaporator Frost Sensor: 25°F +/- 5°F, circuit opens
Filter: MERV 8, washable
Dehumidistat Control Accuracy: +/- 6%RH with
LOCATION CONSIDERATIONS
1.Install Unit Indoors: Do not expose to elements.
2.Drain Accessibility: If a drain is not located in the installation area, a condensate pump may be required.
3.Power: Dedicated outlet within 8 feet of unit.
4.Filter Access: Allow for 12” clearance on one side of the unit for removal of filter. (Figure 1)
5.Inlet: If inlet is not ducted, a minimum of 6” of open space is required from the inlet panel to an adjacent surface.
Figure 1 – Filter | TOP VIEW | 6" MINIMUM CLEARANCE |
| FOR PROPER AIR FLOW | |
Access Clearance |
|
|
FILTER |
| 12" MINIMUM CLEARANCE |
| FOR FILTER | |
|
| |
|
| (EITHER SIDE) |
UNPACKING AND CONTENTS
Do not tip unit to remove from carton.
1.Open carton completely using cut line shown along bottom perimeter of carton.
2.Remove all cardboard inner pack (top edges and duct collars).
3.See Figure 2 for opening view and contents.
a.Installation Manual
b.Owner’s Manual
c.Dehumidistat (mounted to inlet panel)
d.Bag with Dehumidistat Cover Plate, Screws (2), Anchors (2)
e.Outlet with Back Flow Damper
f.8 ft. Grounded Power Cord
g.Wiring Access Panel
Figure 2 – Carton | a | b |
|
Opening & Contents | c | ||
|
|
| |
|
|
| d |
| e |
| g |
| f |
| |
|
|
| |
|
|
|