Table of Contents |
| MATERIALS PROVIDED |
|
|
|
Safety Instructions | 1. . . . System. . | Checkout |
|
|
| |||
Overview |
|
| Power Up | . . . 9 | ||||
| .2 |
| . . |
| .10 | |||
Specifications |
|
| Test Mode |
| ||||
. 2 |
| . | . | 10 | ||||
|
|
| Humidity Setting | |||||
Materials Provided |
| .3 . . . . . Offset | . | . | 10 | |||
Location Recommendations | 3. . . | Turning On and Setting Control . . | . . |
| . 11. . | |||
Sequence of Operation | . . . 11. . . . | |||||||
Installation |
|
| ||||||
|
| Troubleshooting |
|
|
| |||
Mount Control |
| 4 |
|
|
| |||
| Error Codes | . . |
| . 11 | ||||
Wiring |
|
|
| |||||
| 5 |
| . . |
| .12. . . . | |||
|
|
| Troubleshooting Guide |
|
MATERIALS PROVIDED |
| MATERIALS NOT PROVIDED |
• |
| • Wires |
• Mounting Screws |
| • Wire Nuts |
• Drywall Anchors |
|
|
• RH Setting Label |
|
|
A
OVERVIEW
LOCATION RECOMMENDATIONS
The Aprilaire® Model 65 Humidifier Control provides control of the humidifier from the living space.. The control allows the homeowner to set and adjust the humidity setting and turn the humidifier on or off from a convenient location.. The Model 65 uses an onboard sensor to monitor the relative humidity in the space in which it is located and displays the measured relative humidity on the digital display..
SPECIFICATIONS
ELECTRICAL
MOUNT CONTROL
•In an area the homeowner wants to monitor and control moisture levels..
•On an interior wall.
•Approximately 5’ off the floor.
•At least 18” from an outside wall.
See Figure 1..
DO NOT MOUNT CONTROL
•In the flow of a supply register.
•Behind doors, in corners or other dead air spaces.
•In direct sunlight, near lighting fixtures, or other appliances that give off heat..
•On an outside or unconditioned area wall.
•In stairwells or near outside doors.
•On a wall with concealed pipes or ductwork.
Input Voltage and Current | Voltage: 24V AC |
| Current: 25mA (nominal), 50mA (max..) at 24V AC |
|
|
Output | Dry Contact, Normally Open – H Terminals |
|
|
|
|
CONTROL |
|
|
|
Humidity Setting Range | 10% – 50% RH |
|
|
Accuracy | |
|
|
Differential | 3% |
|
|
Low Temp | 40°F |
|
|
High Temp | 99°F |
|
|
Figure 1 – Mounting Location
2 | 3 |