WIRING – Model 65 with Model 800 Steam Humidifier
The Model 65 control requires 24VAC.. See Figure 6..
1.Disconnect power from the Model 800 and HVAC system.
2.Connect 24VAC to the C and R terminals on the Model 65..
3.Connect the H terminals on the Model 800 to the H terminals on the Model 65.
4.Snap the Model 65 front cover on the back plate. The
5.Proceed to SYSTEM CHECKOUT on page 9..
NOTE: If the Model 800 Steam Humidifier is installed with a Model 850 Fan Pack, the Model 65 Control can be powered from the 24VAC secondary wires on the Model 800 transformer, by splicing into the wires using tap connectors.. See Figure 7..
Figure 6 – Recommended Wiring for Model 65 Control and Model 800 Steam Humidifier