Setup & Testing
Ventilation System Settings Table
|
| Factory default setting (bold) |
System setting | Description | and setting range |
Fresh Air Vent Installed | Selects if ventilation is installed.. | No |
| (If set to no, no other ventilation settings will be available.) | Yes |
Setup & Testing
System test menu
The system test menu is used to test a system after installation.. The outputs of the Home Comfort Control can be manually activated to test their function.. The instructions below show how to enter the test mode and turn outputs on and off..
Fresh Air Forces Fan | Selects if ventilation forces the fan on.. | No |
|
| Yes |
Fresh Air Setup | Selects if ventilation is configured through the ASHRAE setup | Timed |
| or Timed. If ASHRAE setup is selected, the hourly ventilation | ASHRAE |
| time will be calculated using the ASHRAE recommendations.. |
|
| If Timed |
|
| determined based on the Fresh Air Time value.. |
|
Fresh Air Time | Selects how many minutes per hour that ventilation will be | 30 MIN/HR |
| active.. (Only available if fresh air setup is set to timed..) | 0 to 60 MIN/HR |
High Limit Outdoor | Selects if ventilation is disabled if the outdoor temperature | No |
Temp | exceeds the outdoor high limit. (Only available if fresh air setup | Yes |
| is set to timed and an outdoor temperature sensor is installed..) |
|
How to enter the system test menu:
Press [MODE] to set system to off..
Press and hold [FAN] and [MODE] for three seconds to enter system test mode..
The first screen of the installer test displays the equipment configuration..
Press [NEXT] to enter the first installation test or [CANCEL] to exit.
SYSTEM TEST STEPS
Heating equipment test Cooling equipment test Fan equipment test Humidification equipment test Dehumidification equipment test Ventilation equipment test
Air Cleaning equipment test
Outdoor High Limit | Sets the high temperature limit for ventilation.. (Only available if | 100°F (38°C) |
| high limit outdoor temp set to yes..) | 90°F to 100°F (32°C to 44°C) |
Low Limit Outdoor Temp | Selects if ventilation is disabled if the outdoor temperature | No |
| exceeds the outdoor low limit. (Only available if fresh air setup | Yes |
| is set to timed and an outdoor temperature sensor is installed..) |
|
Outdoor Low Limit | Sets the low temperature limit for ventilation.. (Only available if | 10°F |
| low limit outdoor temp set to yes..) | |
High Limit Indoor RH | Selects if ventilation is disabled if the indoor RH exceeds | No |
| the indoor RH limit.. (Only available if fresh air setup is set to | Yes |
| timed..) |
|
Indoor RH Limit | Sets the high indoor RH limit for ventilation.. (Only available if | 60% |
| high limit indoor RH is set to yes..) | 50% to 70% |
Number of Bedrooms | Selects the number of bedrooms to be used for the ASHRAE | 3 Bedrooms |
| calculation.. (Only available if fresh air setup is set to ASHRAE..) | 1 to 6 Bedrooms |
Number of Occupants | Selects the number of occupants to be used for the ASHRAE | 4 Occupants |
| calculation.. (Only available if fresh air setup is set to ASHRAE..) | 1 to 10 Occupants |
Home Size | Selects the home size to be used for the ASHRAE calculation.. | 2500 SQ FT |
Temperature
Humidity |
Outdoor |
Temperature |
Equipment |
Configuration |
| (Only available if fresh air setup is set to ASHRAE..) | 1000 to 5000 SQ FT |
|
|
|
Fresh Air CFM | Selects the ventilation CFM to be used for the ASHRAE | 60 CFM |
| calculation.. (Only available if fresh air setup is set to ASHRAE..) | 30 to 200 CFM |
Select Climate | Selects the climate to be used for the ASHRAE calculation.. | Normal |
| (Only available if fresh air setup is set to ASHRAE..) | Very Hot/Humid |
|
| Very Cold |
ASHRAE Cycle Time | Displays the Fresh Air Time calculated by the ASHRAE | Minutes/Hour |
| standard.. (Only displayed if fresh air setup is set to ASHRAE..) |
|
Each equipment test will begin with the selection of turning on the output or stage as shown below..
Press or
to change the selection..
Press [NEXT] to accept the selection and proceed to the next step.
If YES is selected, the Home Comfort Control will test the corresponding output. If NO is selected, the Home Comfort Control will proceed to the next step.
Note: In ASHRAE
Temperature
Equipment Test Selection
Humidity
Outdoor Temperature
Test to be run