INSTALLATION

Before Installing the # 75003 Pool Pilot Digital System

Determine that everything needed for installation is on hand

Determine where the Manifold Assembly will be plumbed

Find a suitable mounting location for the Control Unit within proper cord length to the manifold

Plan cord runs for SuperCell Cable and Tri-Sensor Cable

For optional TC or pH control systems, plan for flow cell water feed tubes and acid feed tube and electrical connections

Plan wire runs and wiring connections for source power and optional connections if any;

oDetermine where input power for the Pool Pilot will originate

ƒ directly from a circuit breaker

 

Digital Time clock is used to control the main pump

 

 

 

 

or pump is also running off the breaker

ƒ

from an external Timer or

 

Pool Pilot is to be wired to the same location as the main filter pump

ƒ

from an electronic controller

 

so that it only activated when the pump is energized.

oDetermine whether the input voltage for the Pool Pilot is 230Vac (factory configured) or 115Vac o Determine whether the Pool Pilot will be used to control a single speed pump or a dual speed pump o Determine whether the Pool Pilot will be controlled by an ORP controller (or TCC Option)

o Determine whether the Pool Pilot will be controlled by an Electronic Controller system.

What is included?

Although the manifold assembly may be sold separately, both a manifold and a Pool Pilot Digital Control unit are required for a complete installation and start-up. The standard cell/manifold assembly is available with the following cells: SC-36, SC-48, SC- 60 (residential cells), or the CC-15 (commercial cell). Before attempting the installation, check that the following items have been included with the Pool Pilot Pool Pilot Digital Control unit:

DIGITAL CONTROLLER

Quantity

Item Description

 

1

# 75003 Pool Pilot Digital Control Unit

BOOST MENU SELECT PUMP

 

 

CHECK

 

 

SYSTE

 

 

M

 

AC jumper for 115 Vac configuration

 

1

Tri-Sensor Cable

 

1

SuperCell Cable

 

1

Mounting Template

 

4

Plastic Anchors

 

4

Mounting Screws

 

*2

68mm x 2” metric adapters (#19059)

 

* European Systems only

What is not included

Some of the additional equipment that may be needed to complete the installation:

For any installation

Appropriate gauge electrical wire

½”liquidtite (non-metallic flex) conduit

½” conduit connector for service to the Pool Pilot

Drill

¼” masonry drill bit

For installations using optional equipment

Appropriate gauge electrical wire

½” liquidtite (non-metallic flex) conduit

½” conduit connector for filter pump

Cable for connection for ORP interface (PN # 315-AC)

4-Conductor cable for connection to Electronic Controller option

MOUNTING TEMPLATE

Drill (4) ¼

cations.

Drill o

Sean Assam

9