INSTALLATION

Electrical Connections

The Pool Pilot Digital uses both high and low voltage connections. High voltage connections will be made for providing the direct input power to it. Additional high voltage connections may be made to the filter pump from the Pool Pilot Digital. Low voltage connections will be made to the Tri-Sensor and SuperCell. Additional low voltage connections are provided for optional equipment such as #75008 pH feeder, #75001 Pool Chemistry Controller, or an ORP or electronic control.

Ensure that power is disconnected before wiring this unit.

! DANGER Follow all state / local / NEC (CEC if applicable) electrical codes. Use copper conductors only.

Grounding and Bonding

Connect a ground wire from the primary electrical input to the grounding lug located inside the box. Also ground any piece of high voltage equipment that is connected to the Pool Pilot Digital relay.

The Pool Pilot Digital must also be connected to the pool bonding system with an 8AWG (6AWG for Canada) wire. A lug is provided on exterior of the unit at the bottom.

High Voltage Wiring

Converting from 230 Vac to 115Vac

The #75003 Pool Pilot Digital has been configured at the factory for 230Vac service. Verify that this is the desired input voltage configuration.

If 115Vac input power is required, follow the directions below to convert the input voltage.

If the cover has not been removed, review the steps in Mounting the #75003 Pool Pilot Digital on pg. 12 for instructions on removing the cover and disconnecting the cable plugs at the display board.

Remove the single jumper wire and re-attach as shown in the diagram.

• Locate the jumper wire provided in the installation kit and attach as shown in the diagram.

230 Volt factory configuration

Optional 115 Volt configuration