Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 180
Image 180
162ThinkServer TD100 and TD100x: Hardware Maintenance Manual

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

1804

No more memory (below 1 MB for a PCI,

1.

Make sure that the settings for the adapter and all

 

PCI-X, or PCI Express adapter).

 

 

other adapters in the Configuration/Setup Utility

 

 

 

 

 

 

program are correct.

 

 

2.

If the error code indicates a particular PCI, PCI-X,

 

 

 

or PCI Express slot or device, remove that

 

 

 

device.

 

 

3.

Reseat each adapter.

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Adapter

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

1805

PCI option ROM checksum error.

1.

Remove the failing adapter.

 

 

 

 

2.

Reseat each adapter.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Adapter

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

1806

PCI built-in self-test failure.

1.

Make sure that the settings for the adapter and all

 

 

 

 

 

other adapters in the Configuration/Setup Utility

 

 

 

program are correct.

 

 

2.

If the error code indicates a particular PCI, PCI-X,

 

 

 

or PCI Express slot or device, remove that

 

 

 

device.

 

 

3.

Reseat each adapter.

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Adapter

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 