portion of the LP in accordance with the CARE AND MAINTENANCE INSTRUCTIONS.

CARE AND MAINTENANCE INSTRUCTIONS

The life preserver and inflation system should be checked at least every three months. In addition, the following maintenance should be performed after each time you wear or inflate the LP.

1)Remove and inspect the CO2 cylinder from the inflator.

2)Check all components for dirt or corrosion. Clean or replace.

3)Check that the CO2 cylinder has not been pierced. Replace with MD3090 33gm CO2 cylinder if necessary (contained in MD3090 accessory pack MA7170). Replace with MD3095 33gm CO2 cylinder if necessary (contained in MD3095 accessory pack MA7203).

4)Check the manual lever to ensure it is in the up and ready position, with the green indicator pin properly installed (MD3090 only).

5)To check the oral inflation valve, fully inflate the MD3090 or MD3095 and hold the valve under water. If bubbles appear, deflate and reinflate to test again. Should the leak persist, take your MD3090 or MD3095 to the point of purchase for proper servicing.

6)Visually examine your MD3090 or MD3095 for damage or excessive abrasion, wear, tear or contamination. Particular attention must be paid to the stitching. If in doubt, send it to the point of purchase for evaluation and/or servicing.

7)Reassemble inflation system parts and repack MD3090 or MD3095 as outlined in previous instructions and illustrations.

Leak test: Every three months the LP should be tested for general leakage by orally inflating until firm and let stand overnight. A leaking LP will not hold its firmness and should be replaced.

WARNING: If you are not confident in the self inspection and servicing of your LP, in accordance with these instructions, take your MD3090 or MD3095 LP to the point of purchase for professional servicing or contact Mustang Survival (see contact information on back of manual).

9

Compact Tactical Life Preserver Owner’s Manual

Page 11
Image 11
Mustang Survival MD3095, MD3090 manual Care and Maintenance Instructions