Re-arming Your MD3095
NOTE: A
1)Hold the cover in one hand, reach under the cover with the other hand and grasp the plastic housing of the inflator. Pull the inflator toward you, turning the bladder and cover inside out to fully expose the inflator for
2)If the sensor ring is broken, it has been used or damaged (Fig. 10). Discard the used cylinder/bayonet assembly and replace (MA7203).
3)Check the new cylinder/bayonet assembly to ensure the
in place and the sensor ring is intact (Fig. 10). Ensure that the CO2 cylinder has not been pierced (Fig. 10).
4)Raise, and hold, the lever into the inflator housing.
5)Install a new cylinder/bayonet assembly by engaging bayonet tabs in housing, pushing in and turning clockwise 1/8 turn to a full stop (Fig. 9).
WARNING: PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP.
FIGURE 9 | MD3081 and MD3082 Manual Inflator |
| |
Tab | Cylinder |
| |
Piercing Pin |
|
Service Indicator | 1/8 Turn |
Lever
6)Examine the service indicator (Fig. 8). Ensure the service indicator is GREEN. If the service indicator is red, the mechanism has been fired or is incorrectly fitted and the inflator requires service. See
NOTE: The service indicator must be green before proceeding.