Lenovo TD100X manual ThinkServer TD100 and TD100x Hardware Maintenance Manual

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 120
Image 120
102ThinkServer TD100 and TD100x: Hardware Maintenance Manual

9.Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector1 and 2. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector. If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly installed. Open the retaining clips, remove the DIMM, and then reinsert it.

1

DIMM 1 connector

7

DIMM 7

2

DIMM 2 connector

8

DIMM 10

3

DIMM 3 connector

9

DIMM 12 connector

4

DIMM 4 connector

10

DIMM 11 connector

5

DIMM 5 connector

11

DIMM 9 connector

6

DIMM 6 connector

12

DIMM 8 connector

10.Rotate the power-supply cage assembly back into the server. Press the power-supply cage release tab 1 and rotate the power-supply cage assembly into the chassis.

102ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 120
Image 120
Lenovo TD100X manual ThinkServer TD100 and TD100x Hardware Maintenance Manual