vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Beep code | Description | Action |
|
|
|
1. Reseat the battery. | ||
|
| |
|
| 2. Clear CMOS memory. See |
|
| switches” on page 14 for information about |
|
| how to clear CMOS. |
|
| 3. Replace the following components one at a |
|
| time, in the order shown, restarting the |
|
| server each time: |
|
| a. Battery |
|
| b. (Trained service technician only) System |
|
| board |
|
|
|
Critical SMBUS error occurred. | 1. Reseat the DIMMs. | |
|
| |
|
| 2. Replace the following components one at a |
|
| time, in the order shown, restarting the |
|
| server each time: |
|
| a. DIMMs |
|
| b. (Trained service technician only) System |
|
| board |
|
|
|
No operational memory in system. | 1. Make sure that the system board contains | |
|
| |
|
| the correct number and type of DIMMs; |
|
| install or reseat the DIMMS; then, restart |
|
| the server. |
|
| Important: In some memory |
|
| configurations, the |
|
| sound during POST, followed by a blank |
|
| monitor screen. If this occurs and the Boot |
|
| Fail Count option in the Start Options of |
|
| the Configuration/Setup Utility program is |
|
| enabled, you must restart the server three |
|
| times to reset the configuration settings to |
|
| the default configuration (the memory |
|
| connector or bank of connectors enabled). |
|
| 2. Replace the following components one at a |
|
| time, in the order shown, restarting the |
|
| server each time: |
|
| a. DIMMs |
|
| b. (Trained service technician only) System |
|
| board |
|
|
|
Two short beeps | Information only, configuration has | 1. Run the Configuration/Setup Utility program. |
| changed. | |
| 2. Run the diagnostic programs. | |
|
| |
|
|
|