Lenovo TD100X manual Beep code, Description, Action, Fail Count option in the Start Options of

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 168
Image 168
Fail Count option in the Start Options of

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Beep code

Description

Action

 

 

 

3-1-4

Time-of-day clock failed.

1. Reseat the battery.

 

 

 

 

2. Clear CMOS memory. See “System-board

 

 

switches” on page 14 for information about

 

 

how to clear CMOS.

 

 

3. Replace the following components one at a

 

 

time, in the order shown, restarting the

 

 

server each time:

 

 

a. Battery

 

 

b. (Trained service technician only) System

 

 

board

 

 

 

3-3-2

Critical SMBUS error occurred.

1. Reseat the DIMMs.

 

 

 

 

2. Replace the following components one at a

 

 

time, in the order shown, restarting the

 

 

server each time:

 

 

a. DIMMs

 

 

b. (Trained service technician only) System

 

 

board

 

 

 

3-3-3

No operational memory in system.

1. Make sure that the system board contains

 

 

 

 

the correct number and type of DIMMs;

 

 

install or reseat the DIMMS; then, restart

 

 

the server.

 

 

Important: In some memory

 

 

configurations, the 3-3-3 beep code might

 

 

sound during POST, followed by a blank

 

 

monitor screen. If this occurs and the Boot

 

 

Fail Count option in the Start Options of

 

 

the Configuration/Setup Utility program is

 

 

enabled, you must restart the server three

 

 

times to reset the configuration settings to

 

 

the default configuration (the memory

 

 

connector or bank of connectors enabled).

 

 

2. Replace the following components one at a

 

 

time, in the order shown, restarting the

 

 

server each time:

 

 

a. DIMMs

 

 

b. (Trained service technician only) System

 

 

board

 

 

 

Two short beeps

Information only, configuration has

1. Run the Configuration/Setup Utility program.

 

changed.

 

2. Run the diagnostic programs.

 

 

 

 

 

150ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 168
Image 168