vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

166-400-100

DMC Self Test Result failed tests: xxx where

1.

Disconnect all server and option power cords

 

xxx=flash, ROM, or RAM.

 

from the server, wait 30 seconds, reconnect the

 

 

 

 

 

 

power cords, and retry.

 

 

2.

Update the BIOS code, BMC, service processor,

 

 

 

and diagnostics firmware (see “Updating the

 

 

 

firmware” on page 15).

 

 

 

 

180-197-000

SCSI ASPI driver not installed.

1.

Remove the RAID adapter, if one is installed, and

 

 

 

 

 

run the test again.

 

 

2.

Reseat the SAS/SATA hard disk drive backplane

 

 

 

cables.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. SAS/SATA hard disk drive backplane

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

180-361-003

Failed fan LED test.

1.

Reseat the fan.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Fan

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

180-xxx-000

Diagnostics LED failure.

Run the diagnostic LED test for the failing LED.

 

 

 

 

180-xxx-001

Failed front LED panel test.

1.

Reseat the control-panel assembly cable.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Control-panel assembly cable

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

180-xx-002

Failed diagnostics LED panel test.

1.

Reseat the control-panel assembly cable.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Control-panel assembly cable

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 