ThinkServer TD100 features and specifications (Machine Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206)
The following information is a summary of the features and specifications for Machine Types 6398, 6399, 6419, 6429, 4203, 4204, 4205, and 4206. Depending on the server model, some features might not be available, or some specifications might not apply.
Table 1. Features and specifications
Microprocessor:
vIntel® Pentium®
v4 MB shared
v667, 1066, or 1333 MHz
Note: Use the Configuration/Setup Utility program to determine the type and speed of the microprocessors.
Memory:
vMinimum: 1 GB
v(TD100) Maximum: 32 GB (16 GB in mirrored mode)
v(TD100) Connectors: eight dual inline memory module (DIMM) connectors,
v(TD100x) Maximum: 48 GB (24 GB in mirrored mode)
v(TD100x) Connectors: Twelve
vTypes:
Drives (depending on the model):
vDiskette (optional): External USB diskette drive
vHard disk drive: SATA
vOne of the following IDE drives:
–
–
–
–
Drive bays (depending on the model):
vThree
v(TD100) Four
v(TD100x) Eight
Expansion slots (depending on the model):
vSix expansion slots
–Three PCI Express x8 slots (two x8 links and one x4 link)
–One PCI
–Two
Fans:
Three
Power supply:
670 watt
Size:
vHeight: 440 mm (17.3 in.)
vDepth: 747 mm (29.4 in.)
vWidth: 218 mm (8.6 in.)
vWeight: 20 kg (42 lb) to 34 kg (75 lb) depending upon configuration
Integrated functions:
vBaseboard management controller (BMC) or onboard service processor
vBroadcom 5721 10/100/1000 Ethernet controller on the system board with
v
vIntegrated RAID capability (SATA HostRAID)
vRemote Supervisor Adapter II SlimLine
vTwo serial ports
vOne parallel port
vFour Universal Serial Bus (USB) v2.0 ports (two on front and two on rear)
vKeyboard port
vMouse port
v
vATI ES1000 video controller
–Compatible with SVGA and VGA
–16 MB SDRAM video memory
Diagnostic LEDs:
vFans
vMemory
vPower supply
Acoustical noise emissions:
vSound power, idling: 5.6 bel
vSound power, operating: 6.0 bel
Environment:
vAir temperature:
–Server on: 10° to 35°C (50° to 95°F)
Altitude: 0 to 914 m (2998.0 ft)
–Server off:
Altitude: 0 to 2133 m (7000.0 ft)
vHumidity (operating and storage): 8% to 80%
Heat output:
Approximate heat output in British thermal units (Btu) per hour:
vMinimum configuration: 693 Btu per hour (203 watts)
vMaximum configuration: 1631 Btu per hour (478 watts)
Electrical input:
v
vInput voltage and frequency ranges automatically selected
vInput voltage low range:
–Minimum: 100 V ac
–Maximum: 127 V ac
vInput voltage high range:
–Minimum: 200 V ac
–Maximum: 240 V ac
vInput
–Minimum: 0.21 kVA (all models)
–Maximum: 0.49 kVA
Notes:
1.Power consumption and heat output vary depending on the number and type of optional features installed and the
2.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual
Chapter 1. Introduction 3