vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

035-292-001

Adapter Parameter Set Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

075-xxx-000

Failed power supply test.

Reseat the following components:

 

 

1.

Hot-swap power supply.

 

 

2.

Hot-swap power backplane.

 

 

3.

Replace the following components (depending on

 

 

 

your model):

 

 

 

v Hot-swap power supply

 

 

 

v (Trained service technician only) Non-hot-swap

 

 

 

power supply

 

 

 

 

089-xxx-001

Failed microprocessor test.

1.

Make sure that the BIOS code is at the latest

 

 

 

 

 

level.

 

 

2.

(Trained service technician only) Reseat

 

 

 

microprocessor 1.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time.

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor 1

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

089-xxx-002

Failed optional microprocessor test.

1.

Make sure that the BIOS code is at the latest

 

 

 

 

 

level.

 

 

2.

(Trained service technician only) Reseat

 

 

 

microprocessor 2.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time.

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor 2

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

194ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 212
Image 212
Lenovo TD100X manual Your model