Lenovo TD100 Performing the checkout procedure, Checkpoint codes trained service technicians only

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 189
Image 189
Performing the checkout procedure

Performing the checkout procedure

To perform the checkout procedure, complete the following steps:

1.Is the server part of a cluster? v No: Go to step 2.

v Yes: Shut down all failing servers that are related to the cluster. Go to step 2.

2.Complete the following steps:

a.Check the power supply LEDs, see “Power-supply LEDs” on page 187.

b.Turn off the server and all external devices.

c.Check all internal and external devices for compatibility at http://www.lenovo.com/support.

d.Check all cables and power cords.

e.Set all display controls to the middle positions.

f.Turn on all external devices.

g.Turn on the server. If the server does not start, see “Troubleshooting tables” on page 172.

h.Check the system-error LED on the control panel. If it is lit, check the LEDs on the system board (see “Error LEDs” on page 186).

Important: If the system-error LED on the front of the server is lit but there are no other error indications, clear the BMC log. This log does not clear itself, and if it begins to fill up, the system-error LED will be lit. Also, after you complete a repair or correct an error, clear the BMC log to turn off the system-error LED on the front of the server.

i.Check for the following results:

vSuccessful completion of POST, indicated by a single beep

vSuccessful completion of startup, indicated by a readable display of the operating-system desktop

3.Did a single beep sound and are there readable instructions on the main menu, or was a POST error code displayed?

v Yes: Find the beep code or error code in “POST beep codes” on page 148 or “POST error codes” on page 155; if necessary, see “Solving undetermined problems” on page 215.

vNo: Find the failure symptom in “Troubleshooting tables” on page 172; if necessary, run the diagnostic programs (see “Running the diagnostic programs” on page 189).

If you receive an error, see “Diagnostic error codes” on page 191.

If the diagnostic programs were completed successfully and you still suspect a problem, see “Solving undetermined problems” on page 215.

Checkpoint codes (trained service technicians only)

A checkpoint code identifies the check that was occurring when the server stopped; it does not provide error codes or suggest replacement components. Checkpoint codes are shown on the checkpoint display, which is on the system board. By using the checkpoint display, you do not have to wait for the video to initialize each time that you restart the server.

There are two types of checkpoint codes: complex programmable logic device (CPLD) hardware checkpoint codes and BIOS checkpoint codes. The BIOS checkpoint codes might change when the BIOS code is updated.