Statement 11:

CAUTION:

The following label indicates sharp edges, corners, or joints nearby.

Statement 17:

CAUTION:

The following label indicates moving parts nearby.

To remove a non-hot-swap power supply cage assembly, complete the following steps.

1.Read the safety information that begins on page vii and “Installation guidelines” on page 73.

2.Turn off the server and all attached devices; then, disconnect all power cords and external cables.

3.Unlock and remove the side cover (see “Removing the side cover” on page 78).

Note: It might be helpful to lay the server on its side for the remainder of this procedure.

4.Disconnect the cables from the power supply to the system board and all internal components.

Attention: Support the power supply while you remove the mounting screws. After the screws are removed, the power supply is loose and can damage other components in the server.

5.Lift up the power-supply cage handle and pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place on the chassis.

Chapter 4. Removing and replacing server components 133

Page 151
Image 151
Lenovo TD100X manual Removing and replacing server components