vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

5962

IDE CD or DVD drive configuration error.

1.

Run the Configuration/Setup Utility program and

 

 

 

 

 

load the default settings (see “Using the

 

 

 

Configuration/Setup Utility program” on page 16).

 

 

2.

Reseat the following components:

 

 

 

v CD or DVD drive cable

 

 

 

v CD or DVD drive

 

 

3.

Replace the components listed in step 2 one at a

 

 

 

time, in the order shown, restarting the server

 

 

 

each time.

 

 

4.

(Trained service technician only) Replace the

 

 

 

system board

 

 

 

 

8603

Pointing-device error.

1.

Reseat the pointing device.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Pointing device

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

00012000

Processor machine check error.

1.

(Trained service technician only) Reseat the

 

 

 

 

 

microprocessor.

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

0001295

ECC circuit check.

1.

Reseat DIMMs

 

 

 

 

2.

Replace the DIMMs, one at a time, restarting the

 

 

 

server each time.

 

 

 

 

00019501

Processor 1 is not functioning; check VRM

1.

(Trained service technician only) Reseat

 

and processor LEDs.

 

 

microprocessor 1. If two microprocessors are

 

 

 

 

 

 

installed, remove microprocessor 1 and replace it

 

 

 

with microprocessor 2 to determine if the

 

 

 

microprocessor or the system board failed.

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor 1

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 