Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 214
Image 214
196ThinkServer TD100 and TD100x: Hardware Maintenance Manual

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

166-198-000

BIOS cannot detect ASM. Reseat ASM

1.

Run the diagnostic test again.

 

adapter in correct slot; ASM restart failure.

 

2.

Correct other error conditions (including other

 

Unplug and cold boot server to reset ASM.

 

 

failed systems-management tests and items that

 

 

 

 

 

 

are logged in the Remote Supervisor Adapter II

 

 

 

SlimLine system-error log) and retry.

 

 

3.

Disconnect all server and option power cords

 

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

power cords, and retry.

 

 

4.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

5.

Replace the components listed in step 4 one at a

 

 

 

time, in the order shown, restarting the server

 

 

 

each time.

 

 

 

166-201-000

ISMP indicates I2C errors on bus X.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

166-201-001

ISMP indicates I2C errors on bus P.

1.

(Trained service technician only) Reseat the

 

 

 

 

 

power backplane.

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only) Power

 

 

 

backplane

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

166-201-002

ISMP indicates I2C errors on bus I.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

166-201-003

ISMP indicates I2C errors on bus C.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

166-201-004

ISMP indicates I2C errors on bus M.

1.

Reseat the DIMM.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

166-201-005

ISMP indicates I2C errors on bus S.

1.

Reseat the SAS/SATA hard disk drive backplane

 

 

 

 

 

cables.

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. SAS/SATA hard disk drive backplane

 

 

 

b. System board

 

 

 

 

196ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 214
Image 214
Lenovo TD100X manual Error code, Description, Action, ThinkServer TD100 and TD100x Hardware Maintenance Manual