Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 174
Image 174
156ThinkServer TD100 and TD100x: Hardware Maintenance Manual

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

162

Invalid configuration information or CMOS

1.

Run the Configuration/Setup Utility program,

 

random-access memory (RAM) checksum

 

 

select Load Default Settings, and save the

 

failure.

 

 

 

settings.

 

 

 

 

 

2.

Clear CMOS memory. See “System-board

 

 

 

switches” on page 14 for information about how

 

 

 

to clear CMOS.

 

 

3.

Reseat the following components:

 

 

 

a.

Battery

 

 

 

b. Failing device (If the device is a FRU, it must

 

 

 

 

be reseated by a trained service technician

 

 

 

 

only.)

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. Failing device (If the device is a FRU, it must

 

 

 

 

be replaced by a trained service technician

 

 

 

 

only.)

 

 

 

c. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

163

Time of day not set.

1.

Run the Configuration/Setup Utility program,

 

 

 

 

 

select Load Default Settings, make sure that the

 

 

 

date and time are correct, and save the settings.

 

 

2.

Reseat the battery.

 

 

3.

Clear CMOS memory. See “System-board

 

 

 

switches” on page 14 for information about how

 

 

 

to clear CMOS.

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

175

Service processor flash code damaged or

1.

Restart the server.

 

not loaded.

 

2.

Update the optional Remote Supervisor Adapter II

 

 

 

 

 

SlimLine firmware (see “Updating the firmware”

 

 

 

on page 15.

 

 

3.

Replace the optional Remote Supervisor Adapter

 

 

 

II SlimLine.

 

 

4.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

 

156ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 174
Image 174
Lenovo TD100X manual Error code, Description, Action, ThinkServer TD100 and TD100x Hardware Maintenance Manual