vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action |
| |
|
|
|
|
|
162 | Invalid configuration information or CMOS | 1. | Run the Configuration/Setup Utility program, | |
| ||||
|
| select Load Default Settings, and save the | ||
| failure. |
| ||
|
| settings. | ||
|
|
| ||
|
| 2. | Clear CMOS memory. See | |
|
|
| switches” on page 14 for information about how | |
|
|
| to clear CMOS. | |
|
| 3. | Reseat the following components: | |
|
|
| a. | Battery |
|
|
| b. Failing device (If the device is a FRU, it must | |
|
|
|
| be reseated by a trained service technician |
|
|
|
| only.) |
|
| 4. | Replace the following components one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | Battery |
|
|
| b. Failing device (If the device is a FRU, it must | |
|
|
|
| be replaced by a trained service technician |
|
|
|
| only.) |
|
|
| c. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
163 | Time of day not set. | 1. | Run the Configuration/Setup Utility program, | |
|
| |||
|
|
| select Load Default Settings, make sure that the | |
|
|
| date and time are correct, and save the settings. | |
|
| 2. | Reseat the battery. | |
|
| 3. | Clear CMOS memory. See | |
|
|
| switches” on page 14 for information about how | |
|
|
| to clear CMOS. | |
|
| 4. | Replace the following components one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | Battery |
|
|
| b. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
175 | Service processor flash code damaged or | 1. | Restart the server. | |
| not loaded. | |||
| 2. | Update the optional Remote Supervisor Adapter II | ||
|
| |||
|
|
| SlimLine firmware (see “Updating the firmware” | |
|
|
| on page 15. | |
|
| 3. | Replace the optional Remote Supervisor Adapter | |
|
|
| II SlimLine. | |
|
| 4. | (Trained service technician only) Replace the | |
|
|
| system board. | |
|
|
|
|
|