vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Action | |||
|
|
| |
System shutoff due to VRM over voltage | 1. | (Trained service technician only) Reseat the microprocessor. | |
| |||
| 2. | Replace the following components one at a time, in the order | |
|
| shown, restarting the server each time: | |
|
| a. (Trained service technician only) Microprocessor | |
|
| b. (Trained service technician only) System board | |
|
|
| |
System shutoff due to VRM under voltage | 1. | (Trained service technician only) Reseat the microprocessor. | |
| |||
| 2. | Replace the following components one at a time, in the order | |
|
| shown, restarting the server each time: | |
|
| a. (Trained service technician only) Microprocessor | |
|
| b. (Trained service technician only) System board | |
|
|
| |
System under recommended voltage for +12v | 1. | Reseat the following components: | |
| |||
|
| a. | |
|
| b. (Trained service technician only) | |
|
| the system board | |
| 2. | (Trained service technician only) Replace the system board. | |
|
|
| |
System under recommended voltage on +2.5v | 1. | Reseat the following components: | |
| |||
|
| a. | |
|
| b. (Trained service technician only) | |
|
| the system board | |
| 2. | (Trained service technician only) Replace the system board. | |
|
|
| |
System under recommended voltage on | 1. | Reseat the following components: | |
continuous +5v | |||
| a. | ||
|
| ||
|
| b. (Trained service technician only) | |
|
| the system board | |
| 2. | (Trained service technician only) Replace the system board. | |
|
| ||
System x started a RS485 connection with us | Information only. | ||
|
| ||
We started a RS485 connection with remote | Information only. | ||
system x |
|
| |
|
| ||
We will retry sending alert ID x; when accepted | Information only. | ||
by a remote system, it will have a different ID |
|
| |
|
| ||
Windows blue screen has been captured | Information only. | ||
|
|
|