Lenovo TD100X manual Closed the bezel

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 109
Image 109

9.Check the hard disk drive status indicator to make sure that the hard disk drive is operating correctly. (You might have to restart the server for the drive to be recognized.) If the amber hard disk drive status LED for a drive is lit continuously, it indicates that the drive is faulty and must be replaced. If the amber hard disk drive status LED for a drive is flashing slowly, this indicates that the drive is being rebuilt. If the amber hard disk drive status LED for a drive is flashing rapidly, this indicates that the controller is identifying the drive. If the green hard disk drive activity LED is flashing, this indicates that the drive is in use.

Note: If the server is configured for RAID operation using an optional ServeRAID controller, you might have to reconfigure the disk arrays after replacing hard disk drives. See the ServeRAID documentation for additional information about RAID operation and complete instructions for using ServeRAID Manager.

10.Closed the bezel.

11.Install the side cover (see “Installing the side cover” on page 79.

12.Lock the side cover.

13.Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.

Chapter 4. Removing and replacing server components 91