Lenovo TD100X manual POST error codes

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 173
Image 173
POST error codes

POST error codes

The following table describes the POST error codes and suggested actions to correct the detected problems.

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

062

Three consecutive boot failures using the

1.

Update the system firmware to the latest level

 

default configuration.

 

 

(see “Updating the firmware” on page 15).

 

 

 

 

 

2.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

101

Tick timer internal interrupt failure.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

102

Internal timer channel 2 test failure.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

 

 

151

Real-time clock error.

1.

Reseat the battery.

 

 

 

 

2.

Clear CMOS memory. See “System-board

 

 

 

switches” on page 14 for information about how

 

 

 

to clear CMOS.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

161

Real-time clock battery failure.

1.

Reseat the battery.

 

 

 

 

2.

Clear CMOS memory. See “System-board

 

 

 

switches” on page 14 for information about how

 

 

 

to clear CMOS.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

Chapter 5. Diagnostics 155