Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 211
Image 211
Manual background

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

030-267-001

Central Management Seq error.

1.

Update the microcode for the Serial Attached

 

 

 

 

 

SCSI (SAS)/SATA controller (see “Updating the

 

 

 

firmware” on page 15).

 

 

2.

Update the BIOS code (see “Updating the

 

 

 

firmware” on page 15).

 

 

3.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

035-002-0nn

ServeRAID interface timeout.

1.

Make sure that the ServeRAID controller is

 

 

 

 

 

configured correctly. Obtain the basic and

 

 

 

extended configuration status bytes and see the

 

 

 

ServeRAID documentation for more information.

 

 

2.

Reseat the following components:

 

 

 

a. SAS/SATA hard disk drive backplane cable

 

 

 

b. ServeRAID controller

 

 

3.

Replace the components listed in step 2 one at a

 

 

 

time, in the order shown, restarting the server

 

 

 

each time.

 

 

 

035-230-001

Battery Low.

Replace the battery module on the RAID controller.

 

 

 

035-231-001

Abnormal Battery Temperature.

Replace the battery module on the RAID controller.

 

 

 

 

035-285-001

Adapter Communication Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

 

035-286-001

Adapter CPU Test Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

 

035-287-001

Adapter Local RAM Test Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

 

035-288-001

Adapter NVSRAM Test Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

 

035-289-001

Adapter Cache Test Error.

1.

Update the RAID controller firmware (see

 

 

 

 

 

“Updating the firmware” on page 15).

 

 

2.

Reseat the RAID controller.

 

 

3.

Replace the RAID controller.

 

 

 

 

Chapter 5. Diagnostics 193

Page 211
Image 211
Lenovo TD100X manual Error code, Description, Action