5.Lift up the power-supply cage handle and pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place on the chassis.

6.Disconnect the power supply docking cable assembly 1 from the system board.

7.Using a phillips screwdriver, remove the three screws 2 that secure the docking cable to the chassis; then, remove it from the chassis.

8.If you are instructed to return the power supply, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Installing the hot-swap power supply docking cable assembly

To install a new hot-swap power supply docking cable assembly, complete the following steps:

1.Position the hot-swap power supply docking cable assembly from the inside the server and insert it in the power supply docking cable slot on the rear of the chassis (aligning the holes with the screw holes on the chassis).

2.Secure the hot-swap power supply docking cable assembly to the chassis with the three screws that you removed earlier.

3.Connect the hot-swap power supply docking cable to the system board.

4.Rotate the power supply cage back into the server.

5.Install the power supplies back into the power supply cage.

6.Install the side cover (see “Installing the side cover” on page 79).

7.Lock the side cover.

8.Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.