Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 218
Image 218
200ThinkServer TD100 and TD100x: Hardware Maintenance Manual

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

201-xxx-n99

Failed memory test.

1.

Reseat the DIMMs.

 

Note: n = 1-4 (DIMM pair)

 

2.

Replace the following components one at a time,

 

 

 

99 = Both DIMMs in the pair failed

 

in the order shown, restarting the server each

 

 

time:

 

 

 

 

 

 

a. DIMM pair

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

202-xxx-00n

Failed system cache test.

1.

(Trained service technician only) Reseat

 

 

 

 

 

microprocessor n.

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. (Trained service technician only)

 

 

 

Microprocessor n

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

215-xxx-000

Failed CD or DVD test.

1.

Run the test again with a different CD or DVD.

 

 

 

 

2.

Reseat the CD or DVD drive cable.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. CD or DVD drive

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

217-xxx-000

Failed fixed disk test.

1.

Reseat hard disk drive 1.

 

Note: If RAID is configured, the fixed disk

 

2.

Replace hard disk drive 1.

 

number refers to the RAID logical array.

 

 

 

 

 

 

 

217-xxx-001

Failed fixed disk test.

1.

Reseat hard disk drive 2.

 

Note: If RAID is configured, the fixed disk

 

2.

Replace hard disk drive 2.

 

number refers to the RAID logical array.

 

 

 

 

 

 

 

217-xxx-002

Failed fixed disk test.

1.

Reseat hard disk drive 3.

 

Note: If RAID is configured, the fixed disk

 

2.

Replace hard disk drive 3.

 

number refers to the RAID logical array.

 

 

 

 

 

 

 

217-xxx-003

Failed fixed disk test.

1.

Reseat hard disk drive 4.

 

Note: If RAID is configured, the fixed disk

 

2.

Replace hard disk drive 4.

 

number refers to the RAID logical array.

 

 

 

 

 

 

 

200ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 218
Image 218
Lenovo TD100X manual Error code, Description, Action, ThinkServer TD100 and TD100x Hardware Maintenance Manual