Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 217
Image 217
Manual background

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

180-xxx-005

Failed SCSI backplane LED test.

1.

Reseat the following components:

 

 

 

 

 

a. SAS/SATA hard disk drive

 

 

 

b. SAS/SATA hard disk drive backplane cable

 

 

 

c.

RAID adapter

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. SAS/SATA hard disk drive backplane

 

 

 

b. SAS/SATA hard disk drive backplane cable

 

 

 

c.

RAID adapter

 

 

 

d. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

180-xxx-006

Failed memory LED test.

1.

Reseat the DIMM.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

180-xxx-007

Failed power supply fan LED test.

1.

Reseat the power supply.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Power supply

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

180-xxx-008

Failed I/O board LED test.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

180-xxx-009

Failed ActivePCI LED test.

(Trained service technician only) Replace the system

 

 

board.

 

 

 

 

 

 

201-198-000

Memory Test Aborted: Could not run the

1.

Restart the server.

 

test; suspect system board error.

 

2.

Run the diagnostic test again.

 

 

 

 

3.

Reinstall the diagnostic programs (see “Updating

 

 

 

the firmware” on page 15).

 

 

4.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

 

201-198-00n

Memory Test Aborted: Could not run the

1.

Restart the server.

 

test.

 

2.

Run the diagnostic test again.

 

Note: n = 1-9 (programming error).

 

3.

Reinstall the diagnostic programs (see “Updating

 

 

 

 

 

the firmware” on page 15).

 

 

 

 

 

Chapter 5. Diagnostics 199

Page 217
Image 217
Lenovo TD100X manual Error code, Description, Action