vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action |
| |
|
|
|
|
|
Failed SCSI backplane LED test. | 1. | Reseat the following components: | ||
|
| |||
|
|
| a. SAS/SATA hard disk drive | |
|
|
| b. SAS/SATA hard disk drive backplane cable | |
|
|
| c. | RAID adapter |
|
| 2. | Replace the following components one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. SAS/SATA hard disk drive backplane | |
|
|
| b. SAS/SATA hard disk drive backplane cable | |
|
|
| c. | RAID adapter |
|
|
| d. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
Failed memory LED test. | 1. | Reseat the DIMM. | ||
|
| |||
|
| 2. | Replace the following components one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. DIMM | |
|
|
| b. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
Failed power supply fan LED test. | 1. | Reseat the power supply. | ||
|
| |||
|
| 2. | Replace the following components one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | Power supply |
|
|
| b. (Trained service technician only) System | |
|
|
|
| board |
|
|
| ||
Failed I/O board LED test. | (Trained service technician only) Replace the system | |||
|
| board. |
| |
|
|
| ||
Failed Active™ PCI LED test. | (Trained service technician only) Replace the system | |||
|
| board. |
| |
|
|
|
|
|
Memory Test Aborted: Could not run the | 1. | Restart the server. | ||
| test; suspect system board error. | |||
| 2. | Run the diagnostic test again. | ||
|
| |||
|
| 3. | Reinstall the diagnostic programs (see “Updating | |
|
|
| the firmware” on page 15). | |
|
| 4. | (Trained service technician only) Replace the | |
|
|
| system board. | |
|
|
|
|
|
Memory Test Aborted: Could not run the | 1. | Restart the server. | ||
| test. | |||
| 2. | Run the diagnostic test again. | ||
| Note: n = | |||
| 3. | Reinstall the diagnostic programs (see “Updating | ||
|
| |||
|
|
| the firmware” on page 15). | |
|
|
|
|
|