Diagnostic error codes
The following table describes the error codes that the diagnostic programs might generate and suggested actions to correct the detected problems.
If the diagnostic programs generate error codes that are not listed in the table, make sure that the latest levels of BIOS, Remote Supervisor Adapter II SlimLine, and ServeRAID code are installed.
In the error codes, x can be any numeral or letter. However, if the
000The server passed the test. Do not replace a CRU or FRU.
195The Esc key was pressed to end the test. Do not replace a CRU or FRU.
197This is a warning error, but it does not indicate a hardware failure; do not replace a CRU or FRU. Take the action that is indicated in the Action column but do not replace a CRU or a FRU. See the description of Warning in “Diagnostic text messages” on page 190 for more information.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
Test aborted. | 1. | Check the diagnostic logs for messages that | |
|
| ||
|
|
| indicate the cause of the error, and take the |
|
|
| indicated action. |
|
| 2. | From the diagnostic programs, run Quick Memory |
|
|
| Test All Banks; then, if an error is detected, take |
|
|
| the indicated action. |
|
| 3. | Reinstall and, if necessary, update the BIOS code |
|
|
| on the server; then, run the test again (see |
|
|
| “Updating the firmware” on page 15). |
|
|
|
|
Test failed, where | 1. | Check the diagnostic logs for messages that | |
| v x of 0 = ECC logic on system board | ||
|
| indicate the cause of the error, and take the | |
| v x of 1 = ECC logic on DIMM |
| indicated action. |
|
| 2. | From the diagnostic programs, run Quick Memory |
|
|
| Test All Banks; then, if an error is detected, take |
|
|
| the indicated action. |
|
| 3. | From the diagnostic programs, run the ECC test |
|
|
| again; then, if an error is detected, take the |
|
|
| indicated action. |
|
| 4. | Reseat the DIMM. |
|
| 5. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. DIMM |
|
|
| b. (Trained service technician only) System |
|
|
| board |
|
|
|
|