Diagnostic error codes

Diagnostic error codes

The following table describes the error codes that the diagnostic programs might generate and suggested actions to correct the detected problems.

If the diagnostic programs generate error codes that are not listed in the table, make sure that the latest levels of BIOS, Remote Supervisor Adapter II SlimLine, and ServeRAID code are installed.

In the error codes, x can be any numeral or letter. However, if the three-digit number in the central position of the code is 000, 195, or 197, do not replace a CRU or FRU. These numbers appearing in the central position of the code have the following meanings:

000The server passed the test. Do not replace a CRU or FRU.

195The Esc key was pressed to end the test. Do not replace a CRU or FRU.

197This is a warning error, but it does not indicate a hardware failure; do not replace a CRU or FRU. Take the action that is indicated in the Action column but do not replace a CRU or a FRU. See the description of Warning in “Diagnostic text messages” on page 190 for more information.

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

001-198-000

Test aborted.

1.

Check the diagnostic logs for messages that

 

 

 

 

 

indicate the cause of the error, and take the

 

 

 

indicated action.

 

 

2.

From the diagnostic programs, run Quick Memory

 

 

 

Test All Banks; then, if an error is detected, take

 

 

 

the indicated action.

 

 

3.

Reinstall and, if necessary, update the BIOS code

 

 

 

on the server; then, run the test again (see

 

 

 

“Updating the firmware” on page 15).

 

 

 

 

001-250-00x

Test failed, where

1.

Check the diagnostic logs for messages that

 

v x of 0 = ECC logic on system board

 

 

indicate the cause of the error, and take the

 

v x of 1 = ECC logic on DIMM

 

indicated action.

 

 

2.

From the diagnostic programs, run Quick Memory

 

 

 

Test All Banks; then, if an error is detected, take

 

 

 

the indicated action.

 

 

3.

From the diagnostic programs, run the ECC test

 

 

 

again; then, if an error is detected, take the

 

 

 

indicated action.

 

 

4.

Reseat the DIMM.

 

 

5.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

Chapter 5. Diagnostics 191

Page 209
Image 209