vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

1962

A hard disk drive does not contain a valid

1. Make sure that a bootable operating system is

 

boot sector.

 

installed.

 

 

 

 

2. Run the hard disk drive diagnostic tests.

 

 

3. Reseat the following components, depending on

 

 

the server model:

 

 

v Hot-swap and non-hot-swap models:

 

 

a.

Hard disk drive

 

 

b. Hard disk drive cable

 

 

c.

Optional adapter cable

 

 

d.

SAS/SATA backplane

 

 

v Simple-swap models:

 

 

a.

Hard disk drive

 

 

b. Hard disk drive cable

 

 

c.

Optional adapter cable

 

 

d.

SATA backplate

 

 

4. Replace the following components one at a time,

 

 

depending on the server model, in the order

 

 

shown, restarting the server each time:

 

 

v Hot-swap and non-hot-swap models:

 

 

a.

Hard disk drive

 

 

b. Hard disk drive cable

 

 

c.

Optional adapter cable

 

 

d.

SAS/SATA backplane

 

 

v Simple-swap models:

 

 

a.

Hard disk drive

 

 

b. Hard disk drive cable

 

 

c.

Optional adapter cable

 

 

d.

SATA backplate

 

 

5. (Trained service technician only) Replace the

 

 

system board.

 

 

 

 

2462

Video configuration error occurred.

1. Reseat the video adapter, if one is installed.

 

 

 

 

2. (Trained service technician only) Replace the

 

 

system board.

 

 

 

 

164ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 182
Image 182
Lenovo TD100X manual ThinkServer TD100 and TD100x Hardware Maintenance Manual