Lenovo TD100X manual Error code, Description, Action

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 178
Image 178
160ThinkServer TD100 and TD100x: Hardware Maintenance Manual

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

178x

Fixed disk error.

1.

Run the hard disk drive diagnostic tests on drive

 

Note: x is the drive that has the error.

 

 

x (see “Running the diagnostic programs” on

 

 

 

 

 

 

page 189.

 

 

2.

Reseat the hard disk drive cables.

 

 

3.

Replace the hard disk drive cables.

 

 

4.

Run the hard disk drive diagnostics tests on drive

 

 

 

x.

 

 

 

5.

Reseat the following components, depending on

 

 

 

the server model:

 

 

 

v Hot-swap and non-hot-swap models:

 

 

 

a. Hard disk drive x

 

 

 

b. Hard disk drive x cable

 

 

 

c.

Optional adapter cable

 

 

 

d.

SAS/SATA backplane

 

 

 

v Simple-swap models:

 

 

 

a. Hard disk drive x

 

 

 

b. Hard disk drive x cable

 

 

 

c.

Optional adapter cable

 

 

 

d.

SATA backplate

 

 

6.

Replace the following components one at a time,

 

 

 

depending on the server model, in the order

 

 

 

shown, restarting the server each time:

 

 

 

v Hot-swap and non-hot-swap models:

 

 

 

a. Hard disk drive x

 

 

 

b. Hard disk drive cable

 

 

 

c.

Optional adapter cable

 

 

 

d.

SAS/SATA backplane

 

 

 

v Simple-swap models:

 

 

 

a. Hard disk drive x

 

 

 

b. Hard disk drive x cable

 

 

 

c.

Optional adapter cable

 

 

 

d.

SATA backplate

 

 

7.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

 

1800

Unavailable PCI hardware interrupt.

1.

Run the Configuration/Setup Utility program and

 

 

 

 

 

adjust the adapter settings.

 

 

2.

Remove each adapter one at a time, restarting

 

 

 

the server each time, until the problem is isolated.

 

 

 

 

 

160ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 178
Image 178
Lenovo TD100X manual Error code, Description, Action, ThinkServer TD100 and TD100x Hardware Maintenance Manual