vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

166-201-006

ISMP indicates I2C errors on bus O.

1.

(Trained service technician only) Control-panel

 

 

 

 

 

assembly.

 

 

2.

Replace the components one at a time, in the

 

 

 

order shown, restarting the server each time:

 

 

 

a. (Trained service technician only)

 

 

 

Control-panel assembly.

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

166-201-007

ISMP indicates I2C errors on bus M0.

1.

Reseat the DIMM.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

166-201-008

ISMP indicates I2C errors on bus M1.

1.

Reseat the DIMM.

 

 

 

 

2.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

166-260-000

ASM restart failure.

1.

Disconnect all server and option power cords

 

 

 

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

power cords, and retry.

 

 

2.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

3.

Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

166-342-000

System management BIST indicates failed

1.

Disconnect all server and option power cords

 

tests.

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

 

 

 

power cords, and retry.

 

 

2.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

3.

Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

166-400-000

ISMP Self Test Result failed tests: xxx

1.

Disconnect all server and option power cords

 

where xxx=flash, ROM, or RAM.

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

 

 

 

power cords, and retry.

 

 

2.

Update the BMC firmware (see “Updating the

 

 

 

firmware” on page 15).

 

 

3.

(Trained service technician only) Replace the

 

 

 

system board

 

 

 

 

Chapter 5. Diagnostics 197