vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

System-error log message

Action

Alert not accepted from system x; type:y,

Information only.

sender’s ID:z

 

 

 

ASM Reset -- reason unknown

Information only.

 

 

ASM Reset due to x, Instruction Fault: y

Information only.

 

 

ASM Reset due Watchdog timeout

Information only.

 

 

ASM Reset was caused by restoring default

Information only.

values

 

 

 

ASM Reset was initiated by the user

Information only.

 

 

Cable: Service processor not present

1. Check the pins and connectors on the cable that connects the

 

 

Remote Supervisor Adapter II SlimLine or other service

 

processor adapter to the Remote Supervisor Adapter SlimLine

 

connector on the system board (see “System-board option

 

connectors” on page 12 for the location of the connector).

 

2. Reseat the cable (both ends) from the Remote Supervisor

 

Adapter II SlimLine or other service processor adapter to the

 

Remote Supervisor Adapter SlimLine connector on the system

 

board.

Configuration error recovery on the Inter-connect Information only. network

CPU x over temperature

1.

Make sure that the heat sink has good airflow and is not

 

 

 

obstructed.

 

2.

Reseat the following components:

 

 

a. Heat sink cable

 

 

b. (Trained service technician only) Heat sink

 

 

 

DASD controller removal

1.

Make sure that the onboard SAS/SATA controller cable is not

 

 

 

damaged.

 

2.

Reseat the onboard SAS/SATA controller cable.

 

3.

Replace the onboard SAS/SATA controller cable.

 

 

DHCP failure,no IP@ assigned-

Information only.

RETRYING!,rc=xxx,count=yyy

 

 

 

 

Dialback failed for userid w. Could not connect

Information only.

at phone number x, y, z

 

 

 

 

ENET[eee] DHCP-

Information only.

HstNme=a,DN=b,IP@=ccc.ccc.ccc.ccc

 

 

GW@=ddd.ddd.ddd.ddd, NMsk=fff.fff.fff.fff,

 

 

DNS1@=ggg.ggg.ggg.ggg,

 

 

DNS2@=hhh.hhh.hhh.hhh

 

 

 

 

ENET[eee] IP-Cfg:HstName=x,

Information only.

IP@=ccc.ccc.ccc.ccc, GW@=ddd.ddd.ddd.ddd,

 

 

NetMsk=fff.fff.fff.fff

 

 