vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

166-051-000

System Management: Failed. Unable to

1.

Update the firmware (BIOS, service processor,

 

communicate with ASM. It may be busy.

 

 

and diagnostics; see “Updating the firmware” on

 

Run the test again.

 

 

 

page 15).

 

 

 

 

 

2.

Run the diagnostic test again.

 

 

3.

Correct other error conditions (including failed

 

 

 

systems-management tests and items that are

 

 

 

logged in the Remote Supervisor Adapter II

 

 

 

SlimLine system-error log) and retry.

 

 

4.

Disconnect all server and option power cords

 

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

power cords, and retry.

 

 

5.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

6.

Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

166-060-000

System Management: Failed. Unable to

1.

Update the firmware (BIOS, service processor,

 

communicate with ASM. It may be busy.

 

 

and diagnostics; see “Updating the firmware” on

 

Run the test again.

 

 

 

page 15).

 

 

 

 

 

2.

Run the diagnostic test again.

 

 

3.

Correct other error conditions (including failed

 

 

 

systems-management tests and items that are

 

 

 

logged in the Remote Supervisor Adapter II

 

 

 

SlimLine system-error log) and retry.

 

 

4.

Disconnect all server and option power cords

 

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

power cords, and retry.

 

 

5.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

6.

Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

166-070-000

System Management: Failed. Unable to

1.

Update the firmware (BIOS, service processor,

 

communicate with ASM. It may be busy.

 

 

and diagnostics; see “Updating the firmware” on

 

Run the test again.

 

 

 

page 15).

 

 

 

 

 

2.

Run the diagnostic test again.

 

 

3.

Correct other error conditions (including failed

 

 

 

systems-management tests and items that are

 

 

 

logged in the Remote Supervisor Adapter II

 

 

 

SlimLine system-error log) and retry.

 

 

4.

Disconnect all server and option power cords

 

 

 

from the server, wait 30 seconds, reconnect the

 

 

 

power cords, and retry.

 

 

5.

Reseat the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

6.

Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

Chapter 5. Diagnostics 195

Page 213
Image 213
Lenovo TD100X manual Diagnostics