Chapter 5. Diagnostics 149

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Beep code

Description

Action

 

 

 

 

1-2-4

RAM refresh verification failed.

1.

Reseat the DIMMs.

 

 

 

 

2. Replace the following components one at a

 

 

 

time, in the order shown, restarting the

 

 

 

server each time:

 

 

 

a. DIMMs

 

 

 

b. (Trained service technician only) System

 

 

 

board

 

 

 

 

1-3-1

First 64 K RAM test failed.

1.

Reseat the DIMMs.

 

 

 

 

2. Replace the lowest-numbered pair of

 

 

 

DIMMs with an identical known good pair of

 

 

 

DIMMs; then, restart the server. If the beep

 

 

 

code error remains, go to 3b. Return one

 

 

 

DIMM at a time from the failed pair to its

 

 

 

connector, restarting the server after each

 

 

 

DIMM to identify the failed DIMM.

 

 

3. Replace the following components one at a

 

 

 

time, in the order shown, restarting the

 

 

 

server each time:

 

 

 

a. DIMMs

 

 

 

b. (Trained service technician only) System

 

 

 

board.

 

 

 

2-1-1

Secondary DMA register test failed.

(Trained service technician only) Replace the

 

 

system board.

 

 

 

2-1-2

Primary DMA register test failed.

(Trained service technician only) Replace the

 

 

system board.

 

 

 

2-1-3

Primary interrupt mask register test

(Trained service technician only) Replace the

 

failed.

system board.

 

 

 

2-1-4

Secondary interrupt mask register test

(Trained service technician only) Replace the

 

failed.

system board.

 

 

 

2-4-1

Video failed, system believed to be

(Trained service technician only) Replace the

 

operable.

system board.

 

 

 

3-1-1

Timer interrupt test failed.

(Trained service technician only) Replace the

 

 

system board.

 

 

 

3-1-2

Timer 2 test failed.

(Trained service technician only) Replace the

 

 

system board.

 

 

 

 

Chapter 5. Diagnostics 149