4-6-2. Self-diagnostic mode
1.Set the TEST MODE.
2.With all the LCD display segments blinking on the set, press DISPLAY key and the
001 1 Adrs
|
| Simplified contents | |
History code | |||
|
Error display code
3.Hereinafter, each time > N key is pressed, the reference information display changes as follows:
•Contents of the history codes
History code number | Contents | |
|
| |
1 | The first error that occurred. | |
|
| |
N | The last error that occurred. | |
|
| |
The first error from the last one. | ||
|
| |
The second error from the last one. | ||
|
| |
R | Total recording time ( – – – – is displayed | |
for | ||
| ||
|
|
0XX | 1 | # # # # |
0XX |
|
|
N | # # # # |
0XX N1 # # # #
0XX N2 # # # #
0XX R – – – –
• Press .
key to go back to the previous display.
•Description of the error display codes
Contents of fault | Display code | Meaning of code | Simplified | Description | |||
contents | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
No error | 00 | No error | – – – – | No error | |||
|
|
|
|
|
|
| |
|
| 01 | Access target address illegally specified | Adrs | An attempt to access an abnormal address. | ||
|
|
|
|
|
|
| |
Servo system error |
| 02 | HIGH TEMP | Temp | HIGH TEMP | ||
|
|
|
|
|
| ||
| 03 | FOCUS ERROR | Fcus | Focus | |||
|
| ||||||
|
|
|
|
|
|
| |
|
| 04 | SPINDLE ERROR | Spdl | Abnormal rotation of disc | ||
|
|
|
|
|
| ||
TOC error | 11 | TOC ERROR | TOC | Faulty TOC contents | |||
|
|
|
|
|
| ||
Power system error | 12 | READ DATA ERROR | Data | Data could not be read at SYNC | |||
|
|
|
|
|
|
| |
|
| 22 | LOWBATT | LBat | Instantaneous interruption detected. | ||
|
|
|
|
|
|
| |
|
| 31 | OFFSET ERROR | Ofst | Offset error | ||
|
|
|
|
|
|
| |
Offset error | 32 | FE_ABCD_OFFSET_ERR | ABCD | FE ABCD Offset error | |||
|
|
|
|
|
|
| |
|
| 33 | TE_OFFSET_ERR | TE | TE Offset error | ||
|
|
|
|
|
|
| |
|
| 34 | X1_TE_OFFSET_ERR | X1TE | X1 TE Offset error | ||
|
|
|
|
|
|
|
4-6-3. Clearing the error display code
After servicing, reset the error display code.
1.Set the TEST MODE.
2.Pressing the DISPLAY key on the remote control activates the
3.To reset the error display code, press X key (2 times)on the remote control when the code is displayed. (except “R - - -