Sony MX-E500 specifications Adrs, 0XX N1 # # # # 0XX N2 # # # #, Self-diagnosticmode

Models: MX-E500

1 36
Download 36 pages 37.51 Kb
Page 10
Image 10
4-6-2. Self-diagnostic mode

4-6-2. Self-diagnostic mode

1.Set the TEST MODE.

2.With all the LCD display segments blinking on the set, press DISPLAY key and the Self-diagnostic mode is entered.

001 1 Adrs

 

 

Simplified contents

History code

 

Error display code

3.Hereinafter, each time > N key is pressed, the reference information display changes as follows:

Contents of the history codes

History code number

Contents

 

 

1

The first error that occurred.

 

 

N

The last error that occurred.

 

 

N-1

The first error from the last one.

 

 

N-2

The second error from the last one.

 

 

R

Total recording time ( – – – – is displayed

for MZ-E500)

 

 

 

0XX

1

# # # #

0XX

 

 

N

# # # #

0XX N1 # # # #

0XX N2 # # # #

0XX R – – – –

• Press .

key to go back to the previous display.

Description of the error display codes

Contents of fault

Display code

Meaning of code

Simplified

Description

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

No error

00

No error

– – – –

No error

 

 

 

 

 

 

 

 

 

01

Access target address illegally specified

Adrs

An attempt to access an abnormal address.

 

 

 

 

 

 

 

Servo system error

 

02

HIGH TEMP

Temp

HIGH TEMP

 

 

 

 

 

 

 

03

FOCUS ERROR

Fcus

Focus off-center.

 

 

 

 

 

 

 

 

 

 

 

04

SPINDLE ERROR

Spdl

Abnormal rotation of disc

 

 

 

 

 

 

TOC error

11

TOC ERROR

TOC

Faulty TOC contents

 

 

 

 

 

 

Power system error

12

READ DATA ERROR

Data

Data could not be read at SYNC

 

 

 

 

 

 

 

 

 

22

LOWBATT

LBat

Instantaneous interruption detected.

 

 

 

 

 

 

 

 

 

31

OFFSET ERROR

Ofst

Offset error

 

 

 

 

 

 

 

Offset error

32

FE_ABCD_OFFSET_ERR

ABCD

FE ABCD Offset error

 

 

 

 

 

 

 

 

 

33

TE_OFFSET_ERR

TE

TE Offset error

 

 

 

 

 

 

 

 

 

34

X1_TE_OFFSET_ERR

X1TE

X1 TE Offset error

 

 

 

 

 

 

 

4-6-3. Clearing the error display code

After servicing, reset the error display code.

1.Set the TEST MODE.

2.Pressing the DISPLAY key on the remote control activates the self-diagnosis display mode.

3.To reset the error display code, press X key (2 times)on the remote control when the code is displayed. (except “R - - - -” ) (All the data on the 1st, N, N-1 and N-2 will be reset)

— 10 —

Page 10
Image 10
Sony MX-E500 specifications Adrs, 0XX N1 # # # # 0XX N2 # # # #, Self-diagnosticmode, Clearing the error display code