Lenovo TD100X manual No-beep symptoms, Power-On Status to Enable

Models: TD100 TD100X

1 254
Download 254 pages 15.59 Kb
Page 170
Image 170

No-beep symptoms

The following table describes situations in which no beep code sounds when POST is completed.

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

No-beep symptom

Description

Action

 

 

 

 

No beeps occur, and the

 

1.

(Trained service technician only) Reseat the

server operates correctly.

 

 

 

front information panel LED cable.

 

 

 

 

 

2.

(Trained service technician only) Replace

 

 

 

the front information panel LED assembly.

 

 

 

No beeps occur, and

 

See “Solving undetermined problems” on page

there is no video.

 

215.

 

 

 

 

No beeps occur after

The power-on status is Disabled.

1.

Run the Configuration/Setup Utility program

successful completion of

 

 

 

and select Start Options; then, set

POST.

 

 

 

 

Power-On Status to Enable.

 

 

 

 

 

2.

(Trained service technician only) Reseat the

 

 

 

operator information LED assembly.

 

 

3.

(Trained service technician only) Replace

 

 

 

the operator information LED assembly.

 

 

 

 

152ThinkServer TD100 and TD100x: Hardware Maintenance Manual

Page 170
Image 170
Lenovo TD100X manual No-beep symptoms, Power-On Status to Enable